12
Troubleshooting
12.1
Errors and warnings
The water heater can have three different kinds of errors:
•
General errors (see 12.1.1), which are not displayed
•
Displayed errors (see 12.1.2), which are divided in two different groups:
-
Lock out errors: when the cause is removed, you can reset the error to resume
operation. The code is displayed continuously and the exclamation mark blinks.
-
Blocking errors: when the cause is removed, the error resets automatically to
resume operation. The code is displayed continuously and the exclamation
mark blinks.
•
Displayed warnings (see 12.1.3)
Note
It is possible to view the error history of the water heater, refer to Error history (see
10.6).
12.1.1
General errors
Note
For the coding of the connections, refer to the Electrical wiring diagram.
Indication
Cause
Measure
Gas smell
There is a gas leak
-
Close the mains gas valve at once.
-
Do not operate any switches.
-
Avoid open flames.
-
Ventilate the boiler room.
-
Immediately contact your installation
engineer or your local gas company.
The display is off
There is no supply voltage.
Make sure that:
-
the isolator is in ON position.
-
there is power on the isolator.
-
there is power to the electrical
connector block.
The measured voltage must be
230 V
AC
(-15%, +10%).
Defective fuse(s)
Replace the fuse(s).
n
n
0313279_TWISTER II_UKUK_
V1.1, 18-02-2019
73
Содержание TWI 35-200
Страница 6: ...6...
Страница 13: ...User part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 13...
Страница 14: ...14...
Страница 16: ...16 User part...
Страница 18: ...18 User part...
Страница 25: ...Installation Maintenance and Service part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 25...
Страница 26: ...26 User part...
Страница 34: ...34 Installation Maintenance and Service part...
Страница 42: ...Fig Venting systems IMD 1353 R0 C43 C13 C53 B23 C33 42 Installation Maintenance and Service part...
Страница 54: ...54 Installation Maintenance and Service part...
Страница 56: ...56 Installation Maintenance and Service part...
Страница 66: ...66 Installation Maintenance and Service part...
Страница 72: ...72 Installation Maintenance and Service part...
Страница 80: ...80 Installation Maintenance and Service part...
Страница 83: ...Fig Dimensions A D E 3 5 1 3 7 4 1 G 5 2 IMD 1349b R0 0313279_TWISTER II_UKUK_V1 1 18 02 2019 83...
Страница 87: ...13 6 Declaration of conformity 0313279_TWISTER II_UKUK_V1 1 18 02 2019 87...
Страница 90: ...90 Installation Maintenance and Service part...