Instruction manual TWI 35-130 G/TWI 45-190 G
49
Service shall be carried out at least once a year both on the gas side and on the
water side. The frequency of the maintenance depends, among other things, on
the water quality, the average number of operating hours per day and the set
water temperature.
Remark
Regular maintenance lengthens the life of the device. For determining
the correct maintenance frequency, it is advised to have the service and
maintenance engineer check the gas side and the water side of the device
three months after installation. The maintenance frequency can be determined
on the basis of this check.
Proceed as follows for testing the proper functioning of all components:
1.
Maximally turn the thermostat counterclockwise.
2.
Wait until the fan stops.
3.
Turn the thermostat to its original position. Then draw off water to create a
heat demand.
4.
Check if the heating cycle runs correctly
(7.3 “Heating cycle of the device”)
.
5.
Check the CO
2
-value and adjust this if necessary
(3.11 “Check and adjust
the CO
2
-value”)
.
6.
Check all parts of the flue gas discharge system for proper fastening.
7.
Check the pressure difference of the pressure switch (see the table).
Clean the heat exchanger if the pressure difference is too low
(10.4.3 “Clean heat exchanger”)
.
Pressure difference of air pressure switch
8.
Test the functioning of the expansion valve of the protected cold supply
setup. The water has to flow out in a forceful jet.
9.
Test the functioning of the T&P valve (if applicable). The water has to flow
out in a forceful jet.
10. Check the discharge pipes of the expansion valve and remove any
present scale deposits.
11. Drain the device (see Drain).
10.1 Introduction
10.2 Prepare
maintenance
10 Maintenance
Device
Measured pressure difference over air pressure switch
TWI 35-130
≥ 730 Pa (NAT and LP)
TWI 45-190
≥ 370 Pa (NAT) and ≥ 430 Pa (LP)
Содержание TWI 35-130
Страница 4: ...4 Instruction manual TWI 35 130 G TWI 45 190 G...
Страница 23: ...Instruction manual TWI 35 130 G TWI 45 190 G 23 Device types IMD 0531 R0...
Страница 34: ...34 Instruction manual TWI 35 130 G TWI 45 190 G 4 Conversion to another gas category...
Страница 42: ...42 Instruction manual TWI 35 130 G TWI 45 190 G 8 Shut down...
Страница 52: ...52 Instruction manual TWI 35 130 G TWI 45 190 G Maintenance 10...
Страница 58: ...58 Instruction manual TWI 35 130 G TWI 45 190 G Annex 12...
Страница 61: ...Instruction manual TWI 35 130 G TWI 45 190 G 61...
Страница 62: ...62 Instruction manual TWI 35 130 G TWI 45 190 G...
Страница 63: ...Instruction manual TWI 35 130 G TWI 45 190 G 63...
Страница 64: ...64 Instruction manual TWI 35 130 G TWI 45 190 G 0311935 R0...