![A.O. Smith T-H2-DV Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/a-o-smith/t-h2-dv/t-h2-dv_service-manual_2837871086.webp)
T-H2-DV/T-H2-OS Service Manual
Ver. 1.01
86
CONFIDENTIAL
To sum it up in a chart:
5 minutes have elapsed
since prior operation?
Inlet
thermistor
temperature
Output
thermistor
temperature
Will automatic firing be
activated?
No
Any
Any
NO
Yes
Above 46°F
Any
NO
Yes
Any
Above 37°F
NO
Yes
Any
37°F and below
NO
Yes
46°F and above
37°F and below
YES
Ceramic heating blocks
The blocks will only activate based on what the freeze protection thermostat senses. The thermostat is
located on the intake port for T-H2-DV and left side of compter board for T-H2-OS. Electrical power is
required for this feature to operate.
The heating blocks will activate if the thermostat senses a surrounding temperature below 36.5°F.
Once they are on, the heating blocks will only deactivate if surrounding temperatures reach above
46.4°F
.