T-H2-DV/T-H2-OS Service Manual
Ver. 1.01
59
CONFIDENTIAL
<Description of mode numbers in “Diagnostics Mode” for individual unit>
Diagnostics information
3-digit 7-seg LED on the
computer board
TM-RE30
Mode
#**
unit information (#1 to #4)
Mode
#**
unit information (#1 to #4)
Total operation time
d1 0 to 999 (×100 hours)
1
0 to 9,999 (×10 hours)
ON/OFF cycles
d2 0 to 999 (×1000 cycles)
2
0 to 9,999 (×100 cycles)
Fan motor speed
d3 0 to 999 (×10 rpm)
3
0 to 9,999
Inlet temperature
d4 32 to 212 (
˚
F).
Over 212
˚
F=E5,
under 32
˚
F=E0
4
32 to 212 (
˚
F).
Over 212
˚
F=E5,
under 32
˚
F=E0
Output temperature
d5
5
Mixing temperature
d6
6
Air-Fuel ratio rod current
d7 0 to 999 (×0.1
μ
A)
7
0 to 999 (×0.1
μ
A)
Flow rate
d8 0.0 to 99.9 GPM
8
0 to 9,999 (×10 GPM)
Bypass valve position
d9 0 to 999 (×10)
Fully closed position=0
9
0 to 9,999
Fully closed position=0
Ratio of hot water and cold
water
d10 0 to 999
10 0 to 999
Error code history: displays
most recent error code
d11
Error code history: displays
most recent error code
11
Error code history: displays
most recent error code
Error code history: displays 2
nd
most recent error code
d12
Error code history: displays
2
nd
most recent error code
12
Error code history: displays 2
nd
most recent error code
Error code history: displays 3
rd
most recent error code
d13
Error code history: displays
3
rd
most recent error code
13
Error code history: displays 3
rd
most recent error code
Clears memory in error code
history*
d14
Clears memory in error code
history*
14
Clears memory in error code
history*
N/A
d15
N/A
15
N/A
Air-Fuel ratio stage
d16
0 to 16,
normal condition=6
16
0 to 16,
normal condition=6
Exhaust temperature
(T-H2-DV only)
d17
32 to 212 (
˚
F).
Over 212
˚
F=E5,
under 32
˚
F=E0
17
32 to 212 (
˚
F).
Over 212
˚
F=E5,
under 32
˚
F=E0
Fan motor speed for exhaust
(T-H2-DV only)
d18 0 to 999 (×10 rpm)
18 0 to 9,999