5  Warranty 

 
 

4.1  General warranty

 

 
 
 
 
 
 
 

4.2  Tank warranty

 

 
 
 
 
 
 
 
 
 
 
 
 

4.3  Conditions for 

installation and use 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

If within one year of the original installation date of a storage water heater supplied by 
A.O. Smith, following verification, and at the sole discretion of A.O. Smith, an assembly 
or part (with exclusion of the tank) proves to be defective or fails to function correctly due 
to manufacturing and/or material defects, then A.O. Smith shall repair or replace this 
assembly or part. 
 
 
 
If within 5 years of the original installation date of a storage water heater supplied by 
A.O. Smith, following verification, and at the sole discretion of A.O. Smith, the glass-lined 
steel tank proves to be leaking due to rust or corrosion occurring on the water side, then 
A.O. Smith shall offer to replace the defective storage water heater with an entirely new 
storage water heater of equivalent size and quality. The warranty period given on the 
replacement storage water heater shall be equal to the remaining warranty period of the 
original storage water heater that was supplied. Notwithstanding that stated earlier in this 
article, in the event that unfiltered or softened water is used, or allowed to stand in the 
storage water heater, the warranty shall be reduced to one year from the original 
installation date. 
 
 
 
The warranty set out in articles 1 and 2 will apply solely under the following conditions: 
a.  The storage water heater is installed under strict adherence to A.O. Smith installation 

instructions for the specific model, and the relevant government and local authority 
installation and building codes, rules and regulations in force at the time of 
installation. 

b.  The storage water heater remains installed at the original site of installation. 
c.  The storage water heater is used exclusively with drinking water, which at all times 

can freely circulate (a separately installed heat exchanger is mandatory for heating 
saline water or corrosive water). 

d.  The tank is safeguarded against harmful scaling and lime build-up by means of 

periodic maintenance. 

e.  The water temperatures in the heater do not exceed the maximum setting. 
f.  The water pressure and/or heat load do not exceed the maximum values stated on 

the storage water heater plate. 

g.  The storage water heater is installed in a non-corrosive atmosphere or environment. 
h.  The storage water heater is connected to a protected cold supply arrangement, 

which is: approved by the relevant authority; with sufficient capacity for this purpose; 
supplying a pressure no greater than the working pressure stated on the storage 
water heater; and where applicable by a likewise approved temperature and pressure 
relief valve, fitted in accordance with installation instructions of A.O. Smith applying to 
the specific model of storage water heater, and further in compliance with the 
government and local authority installation and building codes, rules and regulations. 

i.  The storage water heater is at all times fitted with cathodic protection. If sacrificial 

anodes are used for this, these must be replaced and renewed when, and as soon 
as, they are 60% or more consumed. When power anodes are used, it is important to 
ensure that they continue to work properly. 

 
 
 
 
 
 
 
 
 

Содержание STE - 400

Страница 1: ...0311 370 03 2014 Innovation has a name Commercial Electric Storage Water Heater STE 400 500 600 750 1000 STE Installation User and Service Manual Changes Reserved...

Страница 2: ...A O Smith Europa De Run 5305 5503 LW Veldhoven The Netherlands 31 0 40 294 25 00 your installer...

Страница 3: ...arising from unauthorised use use other than that stated in this manual and use other than in accordance with the General Conditions registered at the Chamber of Commerce Refer further to the General...

Страница 4: ...Installation User and Service Manual 4...

Страница 5: ...al specifications 7 Electrical specifications 8 Dimensions 8 Installation 11 Installation diagram 11 Water connections 11 Electrical connections 12 Maintenance 15 Preparation for maintenance 15 Water...

Страница 6: ...Installation User and Service Manual 6...

Страница 7: ...lish hardness 7 0 eH 100 mg l CaCO3 100 ppm CaCO3 Conductivity 125 S cm Acidity pH value 7 0 pH value 9 5 Note If the water specifications deviate from those stated in the table then the tank protecti...

Страница 8: ...X IP 5X Maximum operating pressure kPa bar 600 6 600 6 600 6 600 6 600 6 600 6 Max Setpoint Control Thermostat C 85 85 85 85 85 85 Overheat Thermostat C 95 95 95 95 95 95 1 6 Dimensions Unit STE 400 S...

Страница 9: ...ection Rp Rp Rp Rp Rp 8 Anode connection Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 11 Connection Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 12 Connection Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 13 Connection temp sensor Rp Rp Rp Rp Rp 14 T P connecti...

Страница 10: ...Installation User and Service Manual 10...

Страница 11: ...B hot water supply C circulation pipe F inlet heat exchanger G outlet heat exchanger IMD 0545 R0 0 2 2 Water connections 2 2 1 Warning The installation should be carried out by a competent person in...

Страница 12: ...n valve 5 after the circulation pump to guarantee the direction of circulation 3 Fit two stop valves for servicing 4 4 Connect the circulation pipe according to the installation diagram 2 1 Installati...

Страница 13: ...erminal on the thermostat 6 Connect the earth of the power cable to the earth terminal in the element Electrical Element screw in 1 Remove the cover and gasket from the inspection opening 2 Mount the...

Страница 14: ...er cable to the earth terminal in the element Picture not available Picture not available Connecting an element of 400 VAC 5 Connect the first live L of the power cable to the L1 terminal on the therm...

Страница 15: ...rage water heater Water side maintenance consists of descaling and cleaning the tank cleaning the elements and checking the anodes Cleaning the elements Scale and lime build up prevent effective condu...

Страница 16: ...ferent places The diameter must be at least 60 of the original 1 diameter 3 If the diameter is less than the minimum the anode must be replaced Please contact the supplier manufacturer to order new an...

Страница 17: ...Installation User and Service Manual 17 4 Errors 4 1 Introduction This chapter deals with the following problems with the water heater Water leakage No hot water Insufficient hot water...

Страница 18: ...r The element is switched off 1 Check whether the element is ON 2 Check whether there is power on the connector block of the element 3 Check whether the element s is defective Safety thermostat has cu...

Страница 19: ...been rectified and no other cause can be found isolate the water heater and alert you installation engineer Hot water supply is used up 1 Reduce hot water consumption and give the water heater time to...

Страница 20: ...Installation User and Service Manual 20...

Страница 21: ...tructions for the specific model and the relevant government and local authority installation and building codes rules and regulations in force at the time of installation b The storage water heater r...

Страница 22: ...pursuant to the specified warranty are limited to free delivery from the warehouse of the replacement assemblies parts or storage water heater respectively Shipping labour installation and any other c...

Страница 23: ...Installation User and Service Manual 23 0311 370 R0 0 EN...

Отзывы: