Installation, User and Service Manual
11
2 Installation
2.1 Installation diagram
This figure shows the installation diagram. This diagram is referred to in the sections
describing the actual connection procedure.
Installation diagram
Legend
2. inlet security group
3. T&P-valve (mandatory)
4. stop valve (recommended)
5. non-return valve (mandatory)
6. circulation pump (optional)
A. cold water supply
B. hot water supply
C. circulation pipe
F. inlet heat exchanger
G. outlet heat exchanger
IMD-0545 R0.0
2.2 Water connections
2.2.1
Warning
The installation should be carried out by a competent person, in compliance with general
and locally applicable regulations.
Cold water side
See (A) in the installation diagram (2.1 "Installation diagram").
1. The maximum working pressure of the storage water heater is 10 bar. Because the
pressure in the water pipe at times can exceed 10 bar, you must fit an approved
pressure-reducing valve.
2. Fit a approved inlet security group (2) according local guidelines.