manualshive.com logo in svg
background image

 6 • Powered Anode System

SYSTEM FEEDBACK

LED

Description/
Corrective 
Action

Solid 
(Green)

System is opera  ng 
properly 
(i.e., components are 
installed properly, module 
is powered, and the tank is 
full of water).

1 Flash 
(Red)* 

Anode disconnected.  
Check for loose connec  ons 
and breaks in the wire 
between the control 
module and the anode/
tank.  The tank connec  on 
must be to bare metal (i.e., 
not paint). 

 


Flashes 
(Red)*

Anode shorted.  

1.)  Check for shorted wiring.  
Correct wiring as necessary.

2.)  Check for corrosion on 
top of anode (electrode) 
and clean with a brush.

3.)  Anode may have 
corrosion or contamina  on.  
Clean as described below.  

 

WARNING! 

Electric Shock Risk.  Contact 
with electrical components 
can result in severe injury 
or death from electrical 
shock.  Use a non-contact 
circuit tester to con

fi

 rm that 

power is o

 .

Turn o

  power to the 

Powered Anode System.  
Disconnect power to the 
water heater if it is an 
electric model.  Remove the 
anode and clean it with a 
cloth.


Flashes
(Red)*

Module failure.  Replace the 
control module.

*

 Beeper will sound during error code.

NOTICE:

• 

It will take about 20 seconds for the 
system to indicate an error condi  on. 

• 

It may take several seconds for the 
system to show correct opera  on 
a  er correc  ons are made.

REGULATORY 
NOTICES

FCC (United States of America)

This equipment has been tested and 
found to comply with the limits for 
a Class B digital device, pursuant to 
part 15 of the FCC rules. These limits 
are designed to provide reasonable 
protec  on against interference in a 
commercial installa  on.  This equipment 
generates, uses, and can radiate 
radio frequency energy and, if not 
installed and used in accordance with 
the instruc  on manual, may cause 
interference to radio communica  ons.  
However, there is no guarantee that 
interference will not occur in a par  cular 
installa  on.  If this equipment does 
cause interference to radio or television 
recep  on, which can be determined 
by turning the equipment o

  and on, 

the user is encouraged to try to correct 
the interference by one or more of the 
following measures:

•   Reorient or relocate the receiving 

antenna.

•   Increase the separa  on between the 

equipment and receiver.

•   Connect the equipment into an outlet 

on a circuit di

 erent from that to 

which the receiver is connected.

•   Consult the dealer or an experienced 

radio/TV technician

CAUTION:  Changes or modi

fi

 ca  ons to 

this equipment not expressly approved 
by the party responsible for compliance 
(A.O. Smith) could void the user’s 
authority to operate the equipment.   

ICES-003 (Canada)

This Class B digital apparatus complies 
with Canadian ICES-003.

Cet appareil numérique de la classe B 
est conforme à la norme NMB-003 du 
Canada.

SPECIFICATIONS

Environmental Speci

fi

 ca  ons:

•  Humidity up to 95% non-condensing.

• Temperature, 

opera  onal = -4°F to 

158°F (-20°C to 70°C)

•  Temperature, storage = -40°F to 176°F 

(-40°C to 80°C)

• Vibra  on = 0.5G

Power Supply (Provided):

Input 100-240VAC, 50-60Hz. 0.5A
Output 12V DC, 1.0A

Power Supply Requirements for 
Powered Anode System:

12V @ 150mA

ASSISTANCE

For warranty ques  ons, call: 

800.527.1953 

When calling, be ready to provide the 
following informa  

on: your name, 

address, and telephone number; the 
serial number of your Powered Anode 
System; proof of purchase/installa  on; 
and a clear descrip  on of the problem.

Содержание Product Preservers Powered Anode System

Страница 1: ... YOUR WATER HEATER RETAIN EACH ORIGINAL RECEIPT AS PROOF OF PURCHASE POWERED ANODE SYSTEM USER S GUIDE Table of Contents SAFETY 2 WIRING DIAGRAM 2 INTRODUCTION 3 INSTALLATION 4 SYSTEM FEEDBACK 6 REGULATORY NOTICES 6 SPECIFICATIONS 6 ASSISTANCE 6 LIMITED WARRANTY BACK COVER Page MODULE ANODE ELECTRODE ...

Страница 2: ... water heater s use and care guide This is the safety alert symbol It is used to alert you to poten al physical injury hazards Obey all safety mes sages that follow this symbol to avoid possible property damage serious injury or death Do not remove any permanent instruc ons labels or the data plate from either the outside of the water heater or on the inside of the access panels Keep this manual n...

Страница 3: ...ered Anode System will not be consumed over me and if it is not working properly its alert system will no fy you In short the Powered Anode System measures the low levels of voltage that exist in the tank s water It then supplies the necessary current very slight to help protect the tank s metal parts It may also control water odor NOTICE The powered anode system must remain plugged into a non swi...

Страница 4: ...ucets to relieve the water pressure C Attach a water hose to the drain valve Run the hose to a drain or outdoors D Open the drain valve and drain about five gallons of water from the water heater Water inside the heater will help hold the unit steady while removing the anode rod E Close the water heater drain valve then close the hot water faucets 3 Remove the old anode rod A Locate the anode rod ...

Страница 5: ...ew See instructions in Figure 7 and Figure 9 7 Return the water heater to service A Ensure that the drain valve is closed then open the cold water supply to the refill the water heater B Open a hot water faucet and allow the water to run until it flows with a full stream C Let the water run full stream for three minutes Check for leaks at the anode D Plug the power supply cord into the module Gree...

Страница 6: ... This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc on manual may cause interference to radio communica ons However there is no guarantee that interference will not occur in a par cular installa on If this equipment does cause interference to radio or television recep on which can be determined by turning the equipment ...

Страница 7: ...Powered Anode System 7 NOTES ...

Страница 8: ...System will not void the water heater warranty on the following brands American A O Smith A O Smith Canada GSW John Wood Lochinvar Reliance State Industries U S Craftmaster and Whirlpool WHAT IS NOT COVERED Improper installation or maintenance Failure to follow applicable codes Failure to follow printed instructions Alterations to the part Failure to operate the part at the specified voltage watta...

Отзывы: