Powered Anode System • 5
5
Attach the new
control module:
A.
Set the control module on top of the
water heater. See Figure 5 or Figure 6.
WARNING!
If you have a gas water
heater, place the module as far away
from the draft hood as possible.
The draft hood can get hot during
operation. Also, the draft hood
must not be altered or obstructed.
Improper venting could lead to
serious injury or death from carbon
monoxide poisoning.
B.
Secure the module to the water
heater’s top with two self-tapping
screws (provided).
6
Connect the wiring
harness:
NOTICE:
During the following steps,
plug each harness connector into the
module carefully. To avoid damage,
do not
use excessive force or twist the
connectors during installa
Ɵ
on.
A.
Plug the harness’ red wire connector
into the module (Figure 7).
B.
Plug the harness’ green wire
connector into the module (Figure 7).
C.
Slide the wire harness’ red wire spade
connector onto the anode’s flag
terminal. See Figure 7 and Figure 8.
D.
Secure the green wire’s fork terminal
underneath a jacket screw. See
instructions in Figure 7 and Figure 9.
7
Return the water
heater to service:
A.
Ensure that the drain valve is closed,
then open the cold water supply to
the refill the water heater.
B.
Open a hot water faucet and allow
the water to run until it flows with a
full stream.
C.
Let the water run full stream for
three minutes.
Check for leaks at
the anode.
D.
Plug the power supply cord into the
module.
Green
Red
Green
Red
Red Wire:
Plug into module’s
“Anode” receptacle.
Green Wire:
Plug into module’s
“GND” receptacle.
A
B
Red Wire:
Plug onto anode’s
ŇĂŐƚĞƌŵŝŶĂů͘
Flag Terminal
Anode (installed)
C
Fork Terminal:
D1. Loosen a screw along the water
heater’s jacket top.
D2. Slide the fork terminal
underneath the screw.
D3. Secure the fork terminal by
ƟŐŚƚĞŶŝŶŐƚŚĞƐĐƌĞǁ͘
D
Module (installed)
Heat Shrink
Fork Terminal
Figure 7:
Harness Installation
Figure 9:
Fork Terminal Placement
Fork Terminal
Screw
Secure fork
terminal
underneath
screw head.
Rod
Threads
Flag Terminal(s)
Hex Head
NOTICE:
Some anode models have tw
ŽŇĂŐ
terminals. You may use either one.
Figure 8:
Top of new anode
E.
Plug the external power supply into a
120VAC wall outlet.
F.
Return the water heater to service
according to its user manual. Verify
proper opera
Ɵ
on.
Содержание Product Preservers Powered Anode System