28
Servicing should only be performed by a Qualified Service Technician
TEST 7
–
INDUCER ON
–
PROVER SWITCH AND LOW GAS SWITCH CLOSED.
NO IGNITER OPERATION
TEST 7
Voltage check and continuity check of hot surface igniter
circuit
Continuity check - Power off- Plug removed from E4
receptacles.
Nominal 80 VAC check - Plug in E4- Power "On".
IF.........
THEN............
Continuity is not indicated
between E4 plug pin 2 to 4.
Check wiring and connection from E4 plug to HSI receiving plug.
Replace HSI Assembly.
Continuity is present.
Resistance should be between 11 and 20 Ohms at a temperature of
77°F.
Voltage is not present between
E4, Pin 2 to ground.
Replace ignition board.
Voltage is present.
Continue.
Voltage is not present between
E4, Pin 4 to ground.
Check wiring and plug connections to HSI. Replace HSI.
Voltage is present.
Note ignition board, Flash code LED. HSI should work.
CONDITIONS:
• Power On.
• Plugs in Receptacles.
• Inducer ON.
• 24V at ignition board E1, Pin 10.
• No power to Igniter.
Содержание Master-Fit 100 Series
Страница 2: ......
Страница 19: ...17 Servicing should only be performed by a Qualified Service Technician WHITE RODGERS IGNITION CONTROL BOARD...
Страница 20: ...18 Servicing should only be performed by a Qualified Service Technician GAS CONTROL VALVE BURNER AREA VIEW...
Страница 22: ...20 Servicing should only be performed by a Qualified Service Technician OPERATING SEQUENCE FLOW CHART...
Страница 36: ...34 Servicing should only be performed by a Qualified Service Technician WIRING DIAGRAM...
Страница 37: ...35 Servicing should only be performed by a Qualified Service Technician NOTES...
Страница 38: ...36 Servicing should only be performed by a Qualified Service Technician NOTES...
Страница 39: ...37 Servicing should only be performed by a Qualified Service Technician NOTES...