Code and description
Cause
Measure
F04
(lock out error)
Ignition error
Three unsuccessful
ignition attempts.
No gas.
Make sure that the main gas supply valve
is open. If necessary, open the valve.
Make sure that the manual gas supply
valve, before the gas control valve, is
open. If necessary, open the valve.
Make sure that the gas supply pressure
to the gas control valve is correct, refer
to Gas supply pressure (see section
8.9.3).
•
•
•
Air in the gas pipes.
Bleed the air out of the gas pipe.
Make sure that the gas supply pressure
to the gas control valve is correct, refer
to Gas supply pressure (see section
8.9.3).
•
•
Defect in the hot surface igniter circuit.
Make sure that the hot surface igniter is
installed correctly.
Make sure that the wiring of the hot
surface igniter is not damaged.
Measure the resistance across the hot
surface igniter. This must be between the
36 and 72 Ohm (at room temperature).
Make sure that the hot surface igniter
lights up during ignition.
If necessary, replace the hot surface igniter.
•
•
•
•
Defect in the ionisation circuit.
Make sure that the flame probe is
installed correctly.
Make sure that the wiring of the flame
probe is not damaged.
Measure the ionisation current. This
current must be a minimum of 3 μA
(parameter
109
).
If necessary, replace the wiring and/or
flame probe.
•
•
•
Supply voltage too low.
Make sure that the measured voltage is
230 V
AC
(-15%, +10%).
Bent flame probe is in contact with
metal surface.
Make sure that the flame probe is not
bend.
If necessary, replace flame probe.
•
•
Ceramic part, of the flame probe, is
broken or cracked.
Make sure that the ceramic part of the
flame probe is not broken or cracked in
the vicinity of the burner.
If necessary, replace flame probe.
•
•
0312266_INNOVO_UKUK_V3.0, 2017-02-10
77
Содержание Innovo 12-160
Страница 6: ...6...
Страница 13: ...User part 0312266_INNOVO_UKUK_V3 0 2017 02 10 13...
Страница 14: ...14...
Страница 16: ...16 User part...
Страница 18: ...18 User part...
Страница 24: ...24 User part...
Страница 27: ...Installation Maintenance and Service part 0312266_INNOVO_UKUK_V3 0 2017 02 10 27...
Страница 28: ...28 User part...
Страница 36: ...36 Installation Maintenance and Service part...
Страница 43: ...Fig Venting systems 0312266_INNOVO_UKUK_V3 0 2017 02 10 43...
Страница 58: ...58 Installation Maintenance and Service part...
Страница 70: ...70 Installation Maintenance and Service part...
Страница 83: ...0312266_INNOVO_UKUK_V3 0 2017 02 10 83...
Страница 87: ...13 5 Declaration of conformity 0312266_INNOVO_UKUK_V3 0 2017 02 10 87...
Страница 90: ...90 Installation Maintenance and Service part...
Страница 92: ...92 Installation Maintenance and Service part...