For draining water from the water heater, following steps
needs to be followed:
1. Switch off the electric supply to the water heater.
2. Open the hot water taps until the water is not hot any
more.
3. Close cold water supply.
4. Drain the water by moving the lever of safety valve in the
direction of the arrow as indicated in the diagram. (Fig. 6)
Draining
Fig. 6 Safety valve
5
Caution:
• Once the mounting, plumbing, discharge tube, power connection and water filling
is completed, then only the power supply should be given.
• During repair or periodic maintenance, if necessary, the power cord or Internal
electrical wiring should be replaced by A. O. Smith Authorised service personnel only.
• It is not permitted for the power supply plug and cord to be replaced or altered by
unauthorised people or by the users themselves. This will make the warranty null and
void and may cause the water heater operation hazardous.
Discharge Tube
Safety Valve
Port
Installation of wired remote controller
Fig. 7 Installation of Bracket for
wired remote controller
Fig. 8 Bracket for
wired remote controller
24mm
Wall
For convenience of operation, please install the wired remote controller on the wall near the
water heater. The length of the wire for wired remote controller is approximately 8 feet.
1. The wired remote controller must be installed at a place where it does not get in direct
contact with water.
2. Drill two holes on the wall by using an electric impact drill with 5mm bit.
3.
The holes must be aligned vertically (Fig. 7). Space between two holes should be 24mm (Fig. 8).
4. Fix the bracket on the wall by expansion tubes and screws attached.
Caution:
• Before using the water heater, make sure that it should be completely filled with water.
• Please turn off the power supply to the water heater prior to draining the water heater.
Warning:
This water heater should not be operated with insufficient amount of water.
Failure to do so may result in damage to the water heater & injuries to the users. This
will also make the warranty null & void.
Содержание HSE-SBS-015
Страница 2: ......
Страница 14: ...Circuit Diagram Black Black Blue Thermal Cutout Power Board Element Green Yellow Red Red Red Wired Remote 10...
Страница 19: ......