Instruction manual GWV
23
is
Dimensions (all measurements in mm unless otherwise indicated)
3.4.2
General and electrical specifications
Chimney data
1) Stated lengths and bends apply for both flue gas removal and air supply
Tap capacity
Size
Description
GWV 120
GWV 150
GWV 200
A
Overall height
835
835
835
B
Height of pump conn heat
exchanger outlet
350
350
350
C
Length of appliance
910
1065
1465
D
Length including flow switch
1230
1495
1895
E
Width of appliance
625
625
625
F
Air supply diameter
150
150
200
G
Diameter of flue gas discharge
150
150
200
H
Centre-to-centre distance between air
supply/flue gas outlet
300
300
480
I
Air supply distance
160
240
260
J
Air supply/flue gas discharge distance
185
185
185
K
Height of gas connection
760
760
760
L
Height of drain valve connection
345
345
345
M
Length including pump
1500
1680
2100
1
Supply connection (external)
R 1
1
/
2
R 2
R 2
2
Return connection (internal)
Rp 1
1
/
2
Rp 2
Rp 2
3
Gas connection (external)
R 1
R 1
R 1
4
Drain valve connection (internal)
3
/
4
"
3
/
4
"
3
/
4
"
5
P-valve connection (internal)
3
/
4
"
3
/
4
"
3
/
4
"
Chimney
1
Unit
GWV 120
GWV 150
GWV 200
Not insulated (max. length)
m
8
8
8
Not insulated (number of bends)
-
2
2
2
Not insulated with condensation removal
(max. length)
m
20
20
20
Not insulated with condensation removal
(number of bends)
-
2
2
2
Insulated (max. length)
m
20
20
20
Insulated (number of bends)
-
2
2
2
Tap capacity (Tcold = 10°C)
Unit
GWV 120
GWV 150
GWV 200
Maximum temperature regulated
°C
85
85
85
continuous
∆
T=28°C
l/h
3041
3787
4838
continuous
∆
T=44°C
l/h
1935
2410
3078
continuous
∆
T=50°C
l/h
1703
2121
2709
continuous
∆
T=55°C
l/h
1548
1928
2463
continuous
∆
T=70°C
l/h
1216
1515
1935
Содержание GWV - 120
Страница 2: ...www aosmithinternational com your installer ...
Страница 4: ...4 Instruction manual GWV gis ...
Страница 8: ...Table of contents 8 Instruction manual GWV ...
Страница 12: ...Introduction 12 Instruction manual GWV 1 gis ...
Страница 40: ...Installation 40 Instruction manual GWV 3 is ...
Страница 42: ...Conversion to a different gas category 42 Instruction manual GWV 4 is ...
Страница 46: ...Filling 46 Instruction manual GWV 5 gis ...
Страница 58: ...Starting and running 58 Instruction manual GWV 9 gis ...
Страница 60: ...Shutting down 60 Instruction manual GWV 10 gis ...
Страница 72: ...Service program 72 Instruction manual GWV 12 is ...
Страница 86: ...Troubleshooting 86 Instruction manual GWV 13 gis ...
Страница 88: ...Maintenance frequency 88 Instruction manual GWV 14 is ...
Страница 98: ...Appendices 98 Instruction manual GWV 17 is ...
Страница 100: ...Instruction manual GWV 100 ...
Страница 102: ...0307 971 4 0 UK Index Instruction manual GWV ...