background image

20

LIMITED RESIDENTIAL GAS WARRANTY

b.  Shipping and delivery charges for forwarding the new water heater

or replacement part from the nearest distributor and returning the
claimed defective heater or part to such distributor except in the state
of California where such charges are the manufacturer’s
responsibility.

c.  All cost necessary or incidental for handling and administrative

charges, and for any materials and/or permits required for installation
of the replacement heater or part.

LIMITATION ON IMPLIED WARRANTIES

Implied warranties, including any warranty of merchantability imposed
on the sale of this heater under state law are limited to one year duration
for the heater or any of its parts.  Some states do not allow limitations on
how long an implied warranty lasts, so the above limitations may not
apply to you.

CLAIM PROCEDURE

Any claim under this warranty should be initiated with the dealer who
sold the heater, or with any other dealer handling the warrantor’s
products.  If this is not practical, the owner should contact: A. O. Smith
Water Products Company,  5621 West 115th Street, Alsip, Illinois, 60803
(800) 323-2636.  Canadian customers should contact A. O. Smith
Enterprises, Ltd., P.O. Box 310-768 Erie Street, Stratford, Ontario N5A
6T3, (519) 271-5800.

The warrantor will only honor replacement with identical or similar water
heater or parts thereof which are manufactured or distributed by the
warrantor.

Dealer replacements are made subject to in-warranty validation by
warrantor.

PROOF-OF-PURCHASE AND PROOF-OF-INSTALLATION DATES ARE
REQUIRED TO SUPPORT WARRANTY FOR CLAIM FROM ORIGINAL
OWNER.  THIS FORM DOES NOT CONSTITUTE PROOF-OF-PURCHASE
OR PROOF-OF-INSTALLATION.

DISCLAIMERS

NO EXPRESSED WARRANTY HAS BEEN OR WILL BE MADE IN BEHALF
OF THE WARRANTOR WITH RESPECT TO THE HEATER OR THE
INSTALLATION, OPERATION, REPAIR OR REPLACEMENT OF THE HEATER
OR PARTS.  THE WARRANTOR SHALL NOT BE RESPONSIBLE FOR
WATER DAMAGE, LOSS OF USE OF THE UNIT, INCONVENIENCE, LOSS
OR DAMAGE TO PERSONAL PROPERTY, OR OTHER CONSEQUENTIAL
DAMAGE.  THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF
THIS WARRANTY OR OTHERWISE FOR DAMAGE TO ANY PERSONS
OR PROPERTY, WHETHER DIRECT OR INDIRECT, AND WHETHER ARISING
IN CONTRACT OR IN TORT.

Some states do not allow the limitation or exclusion of incidental or
consequential damages, so the above limitation or exclusion may not
apply to you.

This warranty gives you specific legal rights, and you may also have
other rights which vary from state to state.

Fill out and keep with water heater.

IMPORTANT INFORMATION

   Model Number____________________________________________

   Serial Number_____________________________________________

   Installation Information:

   Date Installed ____________________________________________

   Company's Name _________________________________________

   Street or P.O. Box _________________________________________

   City, State, and Zip Code ___________________________________

   Phone Number ___________________________________________

   Plumber's Name __________________________________________

THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY.  If
the glass lined tank in this water heater shall prove upon examination by
A. O. Smith Corporation (the warrantor) to have leaked during the
warranty period in normal residential use, due to natural corrosion from
potable water therein, the warrantor will furnish the ORIGINAL OWNER
a replacement A. O. Smith water heater of equivalent size and current
model, or a replacement part for any component part which fails in normal
use, in accordance with the warranty terms and conditions specified
below.  THE A. O. SMITH REPLACEMENT MODEL OR PART WILL BE
WARRANTED FOR ONLY THE UNEXPIRED PORTION OF THE ORIGINAL
WARRANTY.  The warranty period will be determined by the original
installation date of the water heater.  PROOF-OF-PURCHASE AND
PROOF-OF-INSTALLATION ARE NECESSARY TO VALIDATE THIS
WARRANTY.  This warranty is not transferable and applies to models
listed in Table 1 which are produced after December 31, 1996.

TABLE 1

WARRANTY PERIOD

     MODEL

TANK

1

     PARTS

2

      FPSE   -75

  6 YEARS

        2 YEARS

When the water heater has been used for other than  single family
residential application: 1.  The  tank warranty shall be reduced  to 1 year.
2. The parts warranty shall be reduced to one year for all models.
Returned parts which meet any of the following conditions are not
covered by this warranty: 1) improper installation or removal, 2) damaged
by other than normal wear, 3) replaced for cosmetic purposes, or 4)
returned with defaced date codes.

CONDITIONS AND EXCEPTIONS

This warranty shall apply only when the water heater is installed and
operated in accordance with 1) all local fire codes and plumbing codes,
ordinances and regulations, 2) the printed instructions provided with it,
3) good industry practices, and 4) proper safety practices such as but
not limited to a properly sized drain pan if installed in an area where
leakage from connections of the tank would result in damage to the area
adjacent to the heater.  In addition, a new temperature and pressure
relief valve, certified by the American Gas Association must have been
properly installed and piped to the nearest drain.

This warranty shall apply only when the heater is:

• owned by the original purchaser;
•   used at temperatures not exceeding the maximum calibrated

setting of its thermostat;

• not subjected to excessive water pressure fluctuations and

not subject to an operating pressure greater than 150 P.S.I.;

• filled with potable water, free to circulate at all times and with the

tank free of damaging water sediment or scale deposits;

• used in a non-corrosive and non-contaminated atmosphere;
• used with factory approved anode(s) installed;
• in its original installation location;
• in the United States, its territories or possessions, and Canada;
• sized in accordance with proper sizing techniques for

residential water heaters;

•  bearing a rating plate which has not been altered, defaced or

removed except as required by the warrantor;

• not used in a closed system without a properly sized and

installed  thermal expansion tank;

• fired at the factory rated input using the fuel stated in the faceof the

rating plate;

• operated with the inner and outer combustion chamber doors in place;
• maintained in accordance with the instructions printed in the

manual included with the heater.

Any accident to the water heater or any part thereof (including freezing,
fire, floods, or lightning), any misuse, abuse or alteration of it, any
operation of it in a modified form, or any attempt to repair tank leaks or
parts, will void this warranty.

SERVICE AND LABOR RESPONSIBILITY

UNDER THIS LIMITED WARRANTY, THE WARRANTOR WILL PROVIDE
ONLY A REPLACEMENT WATER HEATER OR PART THEREOF.  THE
OWNER IS RESPONSIBLE FOR ALL OTHER COSTS.  Such costs may
include but are not limited to:

a.  Labor charges for service, removal, or reinstallation of the water

heater or part thereof.

Содержание FPSE-75

Страница 1: ...XT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THIS APPLIANCE RESIDENTIAL GAS WATER HEATERS OWNER SMANUAL A DIVISION OF A O SMITH CORPORATION McBee South Carolina U S A www hotwater com GET TO KNOW YOUR WATER HEATER 2 GENERAL SAFETY INFORMATION 3 4 INSTALLATION 4 12 OPERATION 12 14 MAINTENANCE AND TROUBLESHOOTING 14 17 ...

Страница 2: ...he Yellow Pages for your A O Smith plumber or contact the A O Smith Water Products Company 5621 W 115th Street Alsip IL 60803 1 800 433 2545 When ordering parts provide complete model and serial numbers see rating plate quantity and name of part desired as listed in fig 1 Standard hardware items may be purchased locally FPSE 75 with Hot Surface Ignition SmartValve VACUUM RELIEF VALVE INSTALL PER L...

Страница 3: ...ind the cause yourself Go to a neighbor s house leaving your doors open to ventilate the house then call your gas supplier or service agent Keep area clear until a service call has been made At times you may not be able to smell an LP gas leak One cause is odor fade which is a loss of the chemical odorant that gives LP gas its distinctive smell Another cause can be your physical condition such as ...

Страница 4: ...g minimum clearances from combustible material of 2 clearance from sides and rear 6 from the front and 24 from the top Standard clearance If clearances stated on the heater differ from standard clearances install water heater according to clearances stated on heater A minimum clearance of 4 must be allowed for access to replaceable parts such as the thermostats drain valve and relief valve A top c...

Страница 5: ... higher than required for domestic water purposes a tempering valve must be installed Please refer to Fig 2 for suggested piping arrangement FIGURE2 CLOSED WATER SYSTEM A closed system will exist if a back flow preventer check valve pressure reducing valve or other similar device is installed in the cold water line between the water heater and the street main or well Excessive pressure may develop...

Страница 6: ...erating main burner Bubbles indicate gas leak To stop leak tighten pipe connections After piping connections are checked turn on main burner With main burner in operation paint pipe joints including flanges pilot gas tubing connections and control inlet and outlet with rich soap and water solution Bubbles indicate gas leak To stop leak tighten flange screws joints and pipe connections Replace part...

Страница 7: ...h information in this manual under LOCATION OF HEATER and VENT TERMINAL INSTALLATIONS and with the National Fuel Gas Code and local codes PLANNING THE VENT SYSTEM Plan the route of the vent system from the discharge of the blower to the planned location of the vent terminal 1 Layout the total vent system to use a minimum of vent pipe and elbows Take into consideration that an elbow will be necessa...

Страница 8: ... the Vent Terminal is being installed on the outside of a finished wall it may be easier to mark both the inside and outside wall Align the holes by drilling a hole through the center of the template from the inside through to the outside The template can now be positioned on the outside wall using the drilled hole as a centering point for the template 3 A MASONRY SIDE WALLS Chisel an opening appr...

Страница 9: ...e of control box as close to inside wall as possible C If flexible cord and strain relief are removed then opening in box must be covered D Remove plastic cap in top of control box and install suitable conduit fitting in enclosure E Splice field wiring into existing wiring using code authorized method wire nuts etc F Be certain that neutral and line connections are not reversed when making these c...

Страница 10: ...roof with only the vent terminal that is included with the unit see Figure 9 A proper flashing or BOOT should be used to seal the pipe where it exits the roof The total vent system should not exceed the thirty 30 equivalent feet of 3 inch pipe or sixty 60 equivalent feet of 4 inch pipe as listed in Table 1 NOTE The equivalent feet of pipe listed above are exclusive of the TEE termination with inst...

Страница 11: ...ELY FLAMMABLE AND MUST NOT BE STORED OR USED NEAR HEAT OR OPEN FLAME ALSO USE ONLY IN A WELL VENTILATED AREA 3 MAKINGTHEJOINT A Cutting Pipe must be squarely cut to allow for the proper interfacing of the pipe end and the fitting socket bottom This can be accomplished with a miter box saw or wheel type cutter Wheel type cutters are not generally recommended for larger diameters since they tend to ...

Страница 12: ... a tendency to slide back while the cement is still wet so hold the joint together for about 15 seconds STEPG G Cleanup and joint movement Remove all excess cement from around the pipe and fitting with a dry cotton rag This must be done while the cement is still soft The joint should not be disturbed immediately after the cementing procedure and sufficient time should be allowed for proper curing ...

Страница 13: ...ice which automatically lights the burner DO NOT TRY TO LIGHT THE BURNER BY HAND 5 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 6 Set thermostat to desired setting 7 Turn on all electrical power to the appliance 8 If the appliance will not operate follow the instructions TO TURN...

Страница 14: ...er temperature settings to reduce scald hazards Valves for reducing the point of use temperature by mixing cold and hot water are available See figure 2 Also available are inexpensive devices that attach to faucets to limit hot water temperatures Contact a licensed plumber or the local plumbing authority SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUTOFF TURN OFF THE MAIN MANUAL GAS SHUTOF...

Страница 15: ...y will operate at their full input Repeat step C above POWER VENTER MAINTENANCE The FPSE 75 must be inspected quarterly Points of inspection are 1 MOTOR Motor must rotate freely Oil every three months of operation with 4 drops of SAE 20 oil see fig 12 2 WHEEL Wheel must be clean of soot ash or any other coating which inhibits either rotation or air flow Remove all foreign material from vent system...

Страница 16: ...LESHOOTING sections If service becomes necessary contact your dealer installer or an authorized service agent Do not attempt to repair the water heater yourself Any work performed by authorized personnel may void the warranty If you are having a problem with your A O Smith water heater and are not pleased with the service you received First please contact your dealer or the A O Smith authorized se...

Страница 17: ...switch Replace control harness Replace blower and motor Replace switch Check for low voltage less than 102 vac have service checked and repaired If voltage is above 102 vac make sure there is not more than 30 Equivalent feet of 3 inch pipe or 60 equivalent feet of 4 inch pipe installed or vent terminal blockage If at least 102 vac less than 30 equivalent feet of 3 inch pipe or 60 equivalent feet o...

Страница 18: ... connectors 3 System wiring harness in good condition and securely connected at both ends Not Applicable 1 Replace control 1 Airflow proving switch stuck closed 2 Airflow proving switch miswired or jumpered WARNING Line Voltage Hazard Can cause property damage severe injury or death Turn off appliance before coming in contact with pressure switch and or electrical connections 1 Airflow proving swi...

Страница 19: ...BLOWER WITHIGNITERCABLECONNECTED MEASURE VOLTAGE AT HSI ELEMENT OUTPUT SEE INSET B 120V NOMINAL CHECK DAMAGED OR BROKEN HSI ELEMENT WARNING Line Voltage Hazard Can cause property damage severe injury or death Only a trained experienced service technician should perform this trouble shooting Be certain to avoid contact with pressure switch and or electrical connections REPLACEHSI CHECK ISTHEAPPLIAN...

Страница 20: ...rrantor will furnish the ORIGINAL OWNER a replacement A O Smith water heater of equivalent size and current model or a replacement part for any component part which fails in normal use in accordance with the warranty terms and conditions specified below THE A O SMITH REPLACEMENT MODEL OR PART WILL BE WARRANTED FOR ONLY THE UNEXPIRED PORTION OF THE ORIGINAL WARRANTY The warranty period will be dete...