Installation
30
Instruction manual BFC
3
is
Explanation of types of installation
Note
Make sure that the chimney flue discharges into an area approved for this
type of installation.
3.9.3
Concentric connections
The table shows the requirements for concentric systems.
Warning
Install flue gas discharge pipe runs with a run-off of 5 mm per metre towards
the water heater.
Flue gas discharge requirements for concentric systems (C13, C33)
Caution
Both conditions stated in the table must be fulfilled.
Even if you use less than the stated maximum number of bends, the maximum
pipe length
still
may not be exceeded.
Even if you use less than the stated maximum pipe length, the maximum
number of bends
still
may not be exceeded.
The following example illustrates how to use the table.
Practical example of concentric flue gas discharge
Example
The figure shows a BFC 30 installation. The water heater must be fitted with 25
m of concentric pipe (C13/C33) and four 90 degree bends. The configuration
must be checked for compliance with the requirements stated in the table.
Installation type
Description
B23
Air for combustion is drawn from the boiler room.
C13
Concentric and/or parallel wall flue terminal.
C33
Concentric and / or parallel roof flue terminal
C43
Water heaters on common air supply and flue gas discharge (concentric
and/or parallel) in multi-storey building.
C53
Air supply and flue gas discharge terminal types mixed.
C63
Water heaters supplied without flue gas discharge materials and/or terminal.
These water heaters must be installed in compliance with local regulations.
Appliance
Diameter
Maximum
length
Maximum
number of
90
o
bends
BFC 28, 30, 50, 60
100/150 mm
40 m
7
BFC 80, 100, 120
130/200 mm
15 m
4
Содержание Cyclone BFC-28
Страница 4: ...E2...
Страница 6: ...4 Instruction manual BFC gis...
Страница 10: ...Contents 8 Instruction manual BFC...
Страница 31: ...Instruction manual BFC 29 is Installation types IMD 0789 R0 C43 C13 C53 B23 C33...
Страница 48: ...Conversion to a different gas category 46 Instruction manual BFC 4 is...
Страница 58: ...Status of the water heater 56 Instruction manual BFC 8 gis...
Страница 62: ...Shutting down 60 Instruction manual BFC 10 gis...
Страница 74: ...Service program 72 Instruction manual BFC 12 is...
Страница 88: ...Service interval 86 Instruction manual BFC 14 is...
Страница 97: ...Instruction manual BFC 95 is...
Страница 100: ...Appendices 98 Instruction manual BFC 17 is 17 4 Declaration of conformity Declaration of conformity...
Страница 102: ...Instruction manual BFC 100...