Instruction manual BFC
37
is
3.11.1
Procedure for checking the supply pressure
To check the supply pressure, proceed as follows:
1. Isolate (10.3 "Isolating the water heater from the mains") the appliance from
the power supply.
2. Carefully remove the covers from the appliance.
3. The electrical section is now visible.
BFC 28 to 60
4. There is a test nipple before the gas control valve (for natural gas
appliances) or before the pressure-reducing valve (for LPG appliances) so
that the supply pressure can be measured.
This test nipple has a sealing screw. Loosen the sealing screw by a few
turns. Do not completely loosen it as it can be difficult to retighten.
BFC 80 to 120
5. The gas control valve has a test nipple that can be used for measuring the
supply pressure.
This test nipple has a sealing screw. Loosen the sealing screw by a few
turns. Do not completely loosen it as it can be difficult to retighten.
6. Open the gas supply and vent the gas supply line via the test nipple.
IMD-1095a R0
IMD-1096a R0
IMD-1097a R0
Содержание Cyclone BFC-28
Страница 4: ...E2...
Страница 6: ...4 Instruction manual BFC gis...
Страница 10: ...Contents 8 Instruction manual BFC...
Страница 31: ...Instruction manual BFC 29 is Installation types IMD 0789 R0 C43 C13 C53 B23 C33...
Страница 48: ...Conversion to a different gas category 46 Instruction manual BFC 4 is...
Страница 58: ...Status of the water heater 56 Instruction manual BFC 8 gis...
Страница 62: ...Shutting down 60 Instruction manual BFC 10 gis...
Страница 74: ...Service program 72 Instruction manual BFC 12 is...
Страница 88: ...Service interval 86 Instruction manual BFC 14 is...
Страница 97: ...Instruction manual BFC 95 is...
Страница 100: ...Appendices 98 Instruction manual BFC 17 is 17 4 Declaration of conformity Declaration of conformity...
Страница 102: ...Instruction manual BFC 100...