Figure 3.

WARNING:

  The  temperature-pressure  relief  valve  should  be 

manually opened once a year.  Caution should be taken to ensure that 

 

(1) no one is in front of or around the outlet of the temperature-

pressure relief valve discharge line, and (2) the water manually 

discharged will not cause any bodily injury or property damage 

because the water may be extremely hot.
If after manually operating the valve, it fails to completely reset and 

continues to release water, immediately close the cold water inlet 

to the water heater, follow the draining instructions, and replace 

the temperature-pressure relief valve with a new one.

WARNING: 

If the temperature-pressure relief valve on the water 

heater weeps this may be due to thermal expansion. The water 

supply serving this solar water heater may have a check valve 

installed.  Contact the water supplier or local plumbing contractor 

on  how  to  control  this  situation.    Do  not  plug  the  temperature-

pressure relief valve.

CLOSED SYSTEM/THERMAL EXPANSION 

 

Most  public  water  systems  in  North  America  are  required  to 

prevent water flowing from points of use (residences, businesses, 

etc.) back into the supply system in order to maintain water quality. 

To accomplish this, back flow preventers such as check valves, 

are installed in the water line going to each point of use. Typically 

the  back  flow  preventer  will  be  installed  at  the  water  meter  or 

inside a building where the supply line enters the building. This 

device allows water to flow into the residence but does not allow 

it to flow back into the water supply. This creates what is known 

as a “Closed System”. As water is heated by the water heater, 

the water in the system attempts to expand, but has nowhere to 

go resulting in an increase in pressure. This increase in pressure 

in the system may cause the temperature-pressure relief valve to 

open to relieve the pressure. Water will drip from the temperature 

and pressure relief valve. Premature tank failure will result if this 

condition is not corrected. To prevent this condition, a properly-

sized  thermal  expansion  tank  should  be  installed  in  the  cold 

water  supply  to  the  water  heater.  Failure  to  install  a  properly 

sized expansion tank in a closed system will void the warranty 

on the water heater in the event of tank failure. It is important 

to follow the thermal expansion tank manufacturers’ installation 

instructions and to adjust the expansion tank pressure to match 

the water supply pressure. Contact a plumbing service agency 

or  your  retail  supplier  regarding  the  installation  of  a  thermal 

expansion tank.

LOCATING THE SOLAR WATER HEATER 

 

If you have a choice of where to install the solar water heater, 

these ideas may help you decide.
1.  Put the solar water heater indoors as close as possible to where 

you use the most hot water.  This water heater is not  

intended for outdoor installation.

2.  It is handy to have a floor drain, tub or sink nearby. That will 

make it easy to drain water from the water heater.  It is also a 

good place to end the drain line of the temperature-pressure 

relief (T & P) valve.

3.  The solar water heater or the pipes and the connections may, 

in time, leak.  Put the water heater in a place where a water 

leak will not damage anything.  

4.  You must not put the water heater in an area where it might 

freeze.  You must turn off the electricity to the water heater 

before you drain it, to protect the heating elements.

5.  Make sure that you are able to reach the drain valve and all 

access panels when the water heater is in place.  This will make 

it easy to service the water heater.

6.  The water heater must be level before you begin the piping.

WATER HEATERS EVENTUALLY LEAK.

 The installation of the 

water heater must be accomplished in such a manner that if the 

tank or any connections should leak, the flow of water will not 

cause damage to the area adjoining the water heater or to lower 

floors of the structure.  When such locations can’t be avoided, a 

suitable drain pan should be installed under the water heater. Such 

a pan should be no greater than 1-1/2 (45mm) inches deep, have 

a minimum length and width of at least two inches (51mm) greater 

than  the  water  heater  dimensions  and  must  be  piped  to  an 

adequate drain. 

WATER 

PIPING     

Содержание Cirrex SUN-80

Страница 1: ...D WARRANTY QUESTIONS SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED IF YOUARE UNSUCCESSFUL PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER I...

Страница 2: ...ey relate to the installation of electric water heaters The service agency must have a thorough understanding of the water heater Instruction Manual SAFE INSTALLATION USE AND SERVICE Your safety and t...

Страница 3: ...33 GENERAL SAFETY...

Страница 4: ...NG TO INSTALL OR OPERATE THE SOLAR WATER HEATER 2 The installation must conform with these instructions and the local code authority having jurisdiction and the requirements of the power company In th...

Страница 5: ...s are intended to produce hot water Water heated to a temperature which will satisfy space heating clothes washing dish washing and other sanitizing needs can scald and permanently injure you upon con...

Страница 6: ...ect to insulation and standby loss requirements making an insulation blanket unnecessary Should you choose to apply an insulation blanket to this heater you should follow these instructions below Fail...

Страница 7: ...locked or reduced in size under any circumstances Excessive length over 30 feet 9 14 m or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve No valve or...

Страница 8: ...event this condition a properly sized thermal expansion tank should be installed in the cold water supply to the water heater Failure to install a properly sized expansion tank in a closed system will...

Страница 9: ...water taps used by these people or at the water heater Valves for reducing point of use temperature by mixing cold and hot water are also available Consult a Qualified Installer or Service Agency Fol...

Страница 10: ...heater until a constant flow of water runs out an opened hot water faucet This will let out air in the solar water heater and the piping Close the faucet and solar loop air vent after all air has been...

Страница 11: ...gth in any ground return path does not exceed 6 feet 1 8 m The circuit conductors contained therein are protected by overcurrent devices rated at 20 amperes or less The conduit or tubing is terminated...

Страница 12: ...hot water for dishwashers The thermostat is factory set at its lowest position which approximates 120 F 49 C Hot and is adjustable if a different water temperature is desired Read all warnings in this...

Страница 13: ...e corrosion protective action of the anode Smelly water may be eliminated or reduced in some water heater models by replacing the anode s with one of less active material and then chlorinating the wat...

Страница 14: ...the thermostat 4 Disconnect the electrical wires from the heating element s by loosening the screws Figure 11 Remove the screw in element s by turning the element s counterclockwise with a 1 1 2 inch...

Страница 15: ...hould be replaced NOTE Whether re installing or replacing the anode rod check for any leaks and immediately correct if found In replacing the anode 1 Turn off power to the water heater 2 Shut off the...

Страница 16: ...Outlet 9006827005 3 Primary Dip Tube 9002549005 4 Element w Gasket 9003950115 5 Thermostat Bracket 9003898215 6 Thermostat w High Limit 9007623015 7 Terminal Cover 9003914015 8 Access Panel 9003900005...

Страница 17: ...1717 NOTES...

Страница 18: ...18 NOTES...

Страница 19: ...1919 NOTES...

Страница 20: ...20...

Отзывы: