SERVICE CHECKLIST
This is not intended to be an all-inclusive list of the problems that the Service Agent may encounter. Any item checked "no" on this
list should be thoroughly investigated and corrective action taken, if required.
SERVICE AGENT: __________________________
INSTALLATION DATE: __________________________
MODEL NUMBER: _________________________
SERVICE DATE: ______________________________
SERIAL NUMBER: _________________________
LOCATION ADDRESS: _________________________
PHONE ( ) ________ - _____________
GAS TYPE - CHECK ONE
NATURAL _____
PROPANE _____
PROPER GAS VALUE VERIFIED
YES ___NO___
I.
CHECK CLEARANCE (CIRCLE ANSWER)
A.
Are exterior clearances adequate ______________________________________________ yes
no
B. Are interior clearances adequate ______________________________________________ yes
no
Comments: _______________________________________________________________
_______________________________________________________________
II.
CHECK MAKEUP AIR REQUIREMENTS
A.
Is the quality of make-up air adequate? _________________________________________ yes
no
Comments: _______________________________________________________________
_______________________________________________________________
B. Is the quantity of make-up air adequate? ________________________________________ yes
no
Comments: _______________________________________________________________
_______________________________________________________________
III.
GAS PRESSURE (FILL IN BLANK) - ALL UNITS ON.
A.
Supply gas pressure ___ inches of w.c. (flowing)
B. Manifold gas pressure (main burner) ___ inches of w.c. (flowing)
Comments: _______________________________________________________________
_______________________________________________________________
IV.
VENTING (CHECK)
A.
Acceptable equivalent footage ________________________________________________ yes
no
B. Proper material ____________________________________________________________ yes
no
C. Proper exterior installation ___________________________________________________ yes
no
D. Condensate will drain _____________________________________________________ yes no
Comments: _______________________________________________________________
_______________________________________________________________
V.
WATER PIPING
Is the system properly sized? ____________________________________________________ yes
no
Is the system properly installed? _________________________________________________ yes
no
Are there any water leaks? ______________________________________________________ yes
no
Does the installation have a recirculating system? ___________________________________ yes
no
If so, is it operational? __________________________________________________________ yes
no
VI.
SAFETY
A.
Air
If exhaust is blocked will unit lockout? __________________________________________ yes
no
If air intake is blocked will unit lockout? _________________________________________ yes
no
B. Water Temperature
- Is the thermostat adjusted to the lowest acceptable temperature? __________________ yes
no
- Does the installation have a mixing valve? _____________________________________ yes
no
- If so, is it operational? _____________________________________________________ yes
no
- What is the outlet temperature of the mixing valve? _______________________________ yes
no
NOTE: To minimize the risk of scalding, the manufacturer recommends storing water at 120°F.
Is a properly rated temperature and pressure relief valve installed? _____________________ yes
no
Is there a properly installed expansion tank? ________________________________________ yes
no
Should there be? ______________________________________________________________ yes
no
C. Electrical
Is the 120 VAC electrical powers supply properly wired? (including polarity) ____________ yes
no
Are all the BTH control covers in place? _________________________________________ yes
no
Is the 120 VAC electrical power supply properly fused? ____________________________ yes
no
D. Flammables
Are flammable materials located in the area of the water heater? or air intake? _________ yes
no
Are flammable vapors located in the area of the water heater? or air intake? ___________ yes
no
E. Gas
If the gas supply is reduced or turned off will the unit turn off? _______________________ yes
no
Comments: _______________________________________________________________
_______________________________________________________________
[This service checklist may be photo copied to assist with BTH service calls].