24
TROUBLESHOOTING
STEP 8 - TEMPERATURE THERMISTOR CHECK
STEP 8. TEMPERATURE THERMISTOR CHECK.
The ohm’s resistance thru a thermistor is interpreted by the control board as a water temperature reading.
• Note tank water temperature on display board or tank a thermometer reading from the T&P valve and
drain valve
• Disconnect plugs from CN 3 and CN 8
• Set multimeter to read “resistance” (20 K scale)
Check the ohm’s resistance from black to black on the CN 3 plug and black to black on the CN 8 plug.
IF…
THEN
Ohm reading does not (approximately) correspond
to table information
Ohm reading does correspond (approximately) to
the table information.
replace
go to St
Note: Thermistors are very reliable unless a wire is cut or
connection loose. A "bad" thermistor temperature sensor is
unlikely to be the problem.
°C
°F
3
40
26,435
21
70
11,974
37.5
100
5,862
49
120
3,780
54.5
130
3,066
60
140
2,503
71
160
1,698
82
180
1,177
W ater Temp
OHMS
Resistance
Upper Temperature Probe Plug
Lower Temperature Probe Plug