4
PRECAUTIONS
DO NOT USE THIS WATER HEATER IF ANY PART HAS
BEEN EXPOSED TO FLOODING OR WATER DAMAGE.
,PPHGLDWHO\FDOODTXDOL¿HGVHUYLFHDJHQF\WRLQVSHFWWKH
ZDWHUKHDWHUDQGWRPDNHDGHWHUPLQDWLRQRQZKDWVWHSV
VKRXOGEHWDNHQQH[W
,IWKHXQLWLVH[SRVHGWRWKHIROORZLQJGRQRWRSHUDWHKHDW
-
HUXQWLODOOFRUUHFWLYHVWHSVKDYHEHHQPDGHE\DTXDOL¿HG
VHUYLFHDJHQF\
1.
([WHUQDO¿UH
2.
'DPDJH
3.
)LULQJZLWKRXWZDWHU
GROUNDING INSTRUCTIONS
7KLVZDWHUKHDWHUPXVWEHJURXQGHGLQDFFRUGDQFHZLWK
the
National Electrical Code
DQGRUORFDOFRGHV7KHVH
FRGHVPXVWEHIROORZHGLQDOOFDVHV)DLOXUHWRJURXQGWKLV
ZDWHUKHDWHUSURSHUO\PD\DOVRFDXVHHUUDWLFFRQWUROV\VWHP
operation.
7KLVZDWHUKHDWHUPXVWEHFRQQHFWHGWRDJURXQGHGPHWDO
SHUPDQHQW ZLULQJ V\VWHP RU DQ HTXLSPHQW JURXQGLQJ
FRQGXFWRU PXVW EH UXQ ZLWK WKH FLUFXLW FRQGXFWRUV DQG
FRQQHFWHGWRWKHHTXLSPHQWJURXQGLQJWHUPLQDORUOHDGRQ
WKHZDWHUKHDWHU
HYDROGEN GAS FLAMMABLE
Explosion Hazard
Flammable hydrogen gases
may be present.
Keep all ignition sources away
from faucet when turning on
hot water.
+\GURJHQ JDV FDQ EH SURGXFHG LQ D KRW ZDWHU V\VWHP
VHUYHGE\WKLVZDWHUKHDWHUWKDWKDVQRWEHHQXVHGIRUD
ORQJSHULRGRIWLPHJHQHUDOO\WZRZHHN\GURJHQ
JDV LV H[WUHPHO\ ÀDPPDEOH 7R UHGXFH WKH ULVN RI LQMXU\
XQGHUWKHVHFRQGLWLRQVLWLVUHFRPPHQGHGWKDWDKRWZDWHU
IDXFHWVHUYHGE\WKLVZDWHUKHDWHUEHRSHQHGIRUVHYHUDO
PLQXWHVEHIRUHXVLQJDQ\HOHFWULFDODSSOLDQFHFRQQHFWHG
WRWKHKRWZDWHUV\VWHP,IK\GURJHQLVSUHVHQWWKHUHZLOO
SUREDEO\EHDQXQXVXDOVRXQGVXFKDVDLUHVFDSLQJWKURXJK
WKHSLSHDVWKHZDWHUEHJLQVWRÀRZ
THERE SHOULD BE
NO SMOKING OR OPEN FLAME NEAR THE FAUCET AT
THE TIME IT IS OPEN.
GENERAL SAFETY INFORMATION
Verify the power to the water heater is turned off before performing any service
procedures. The Enable /Disable switch on front panel disables the 24-volt gas valve.
Electrical supply must be turned off at circuit breaker serving water heater.
Read and understand this instruction
manual and the safety messages
herein before installing, operating or
servicing this water heater.
Failure to follow these instructions and
safety messages could result in death
or serious injury.
This manual must remain with the
water heater.
Water temperature over 125°F (52°C)
can cause severe burns instantly
resulting in severe injury or death.
Children, the elderly and the
physically or mentally disabled are at
highest risk for scald injury.
Feel water before bathing or
showering.
Temperature limiting devices such as
mixing valves must be installed
when required by codes and to
ensure safe temperatures at fixtures.
Explosion Hazard
Overheated water can cause
water tank explosion.
Properly sized temperature and
pressure relief valve must be
installed in the opening provided.
Improper installation, use and service may result
in property damage.
Do not operate water heater if exposed to flooding or
water damage.
•
Inspect anode rods regularly, replace if damaged.
•
Install in location with drainage.
•
Fill tank with water before operation.
•
Properly sized thermal expansion tanks are required on all
closed water systems.
•
Refer to this manual for installation and service.
CAUTION
Содержание ATX-199
Страница 73: ...73 NOTES...
Страница 74: ...74 NOTES...
Страница 75: ...75 NOTES...
Страница 76: ...RU DGGLWLRQDO LQIRUPDWLRQ FRQWDFW 1 800 527 1953 ZZZ KRWZDWHU FRP...