  MAINTENANCE

Electric water heater maintenance consists of cleaning the tank bottom
and removing scale from the heating elements.  Your dealer should be
contacted for tank and element cleaning.  In some instances a hissing
sound may be heard as the scale builds up.  This noise is normal although
the scale should be removed.

Periodically the temperature and pressure relief valve should be checked
to insure that it is in operating condition.  Lift the lever at the top of the
valve several times until the valve seats properly and operates freely.

RELIEF VALVE

The temperature/pressure (T&P) relief valve is rated at 210°F (99°C) and
150 psi (1034kPa).  This valve is a safety device to protect against
abnormally high temperature and pressures.

Never remove T&P valve from the tank and reinstall in the drain line.  If
replacement of the valve is needed, it must be replaced with the
recommended valve and installed in its original location.

If the temperature/pressure relief valve discharges periodically, this may
be due to thermal expansion in a closed water supply system.  Contact
the water supplier or local plumbing inspector on how to correct this
situation.

A thermal expansion tank may be needed to allow water to expand.
Expansion tanks are available from A.O. Smith Water Products Company,
5621 W. 115th Street, Alsip, IL 60803.  Inspect the unit for proper operation.
Do not ignore the water discharge.  Never plug the T&P relief valve.

  DANGER

DANGER OF PERSONAL INJURY FROM SCALDING.  WATER FROM T&P
RELIEF VALVE MAY BE EXTREMELY HOT AND IS NOT TEMPERED.  USE
EXTREME CAUTION WHEN DISCHARGING VALVE.  REPLACEMENT OF
T&P VALVE SHOULD BE DONE BY A TRAINED PROFESSIONAL OR A
LICENSED PLUMBING CONTRACTOR.

At least once a year, the temperature and pressure relief valve must be
checked to ensure that it is in operating condition. Lift the lever at the top
of the valve several times until the valve seats properly and operates
freely.

If water does not flow, valve may be obstructed or corroded.  Remove
valve and inspect for corrosion. Have it replaced with the recommended
valve if necessary.

Removal and inspection of the valve should be done every three years.
Do not try to repair valve.  Doing so will result in improper operation
which may result in a tank explosion.  In areas with poor water conditions,
it may be necessary to remove and inspect the T&P valve more often
than every three years.

ANODE ROD MAINTENANCE

The anode rod is used to protect the tank from corrosion. Water tanks
are equipped with an anode rod.  The submerged rod sacrifices itself to
protect the tank.  Instead of corroding the tank, water ions attack and eat
away the anode rod.  This does not affect the water's taste or color.
The rod must be maintained to keep the tank in operating condition.

Anode deterioration depends on water conductivity, not necessarily
water condition.  It may be necessary to have the anode rod inspected
a few times during the first year to see what effect the water has had.
A corroded or pitted anode rod, in the first year, indicates high water
conductivity and should be checked and or replaced more often than an
anode rod that appears to be fairly clean.  Inspection should be conducted
by a qualified technician.

REPLACEMENT PARTS

Replacement parts may be ordered through dealers, authorized servicers
or distributors.  Refer to Yellow Pages for where to call or contact the
Water Products Company, 5621 West 115th Street, Alsip, IL 60803,
1-800-433-2545.  When ordering parts, specify complete model no.,
serial no., (see rating plate), quantity and name of part desired.  Standard
hardware items should be purchased locally.

TROUBLE SHOOTING ELECTRIC WATER HEATERS

CAUSE

IMPROPERLY SEALED HOT OR COLD
SUPPLY CONNECTIONS, RELIEF VALVE
OR THERMOSTAT THREADS
LEAKAGE FROM OTHER APPLIANCES

OR WATER LINES

THERMAL EXPANSION IN CLOSED
WATER SYSTEM

IMPROPERLY SEATED VALVE

HIGH SULFATE OR MINERAL
CONTENT IN WATER SUPPLY

BACTERIA IN WATER SUPPLY

POWER SUPPLY TO HEATER IS NOT
ON

THERMOSTAT SET TOO LOW

HEATER UNDERSIZED

INCOMING WATER IS UNUSUALLY

COLD (WINTER)

LEAKING HOT WATER FROM PIPES OR
FIXTURES

HIGH TEMPERATURE LIMIT SWITCH

ACTIVATED

THERMOSTAT SET TOO HIGH

HIGH TEMPERATURE LIMIT SWITCH
ACTIVATED

SCALE ACCUMULATION ON ELEMENTS

SEDIMENT BUILD-UP ON TANK
BOTTOM

SOLUTION

TIGHTEN THREADED CONNECTIONS

INSPECT OTHER APPLIANCES NEAR WATER
HEATER

INSTALL THERMAL EXPANSION TANK (DO NOT
PLUG T & P RELIEF VALVE)

CHECK RELIEF VALVE FOR PROPER OPERATION

DRAIN AND FLUSH HEATER THOROUGHLY, AND
REFILL

CHLORINATE WATER SUPPLY

TURN DISCONNECT SWITCH ON OR CONTACT
ELECTRICIAN

REFER TO TEMPERATURE REGULATION

REDUCE HOT WATER USE

ALLOW MORE TIME FOR HEATER TO REHEAT

HAVE PLUMBER CHECK AND REPAIR LEAKS

CONTACT DEALER TO DETERMINE CAUSE:  SEE
TEMPERATURE REGULATION

REFER TO TEMPERATURE REGULATION

CONTACT DEALER TO DETERMINE CAUSE:  SEE
TEMPERATURE REGULATION

CONTACT DEALER TO CLEAN OR REPLACE
ELEMENTS

DRAIN & FLUSH THOROUGHLY

PROBLEM

WATER LEAKS (SEE LEAKAGE CHECKPOINTS
ON PAGE 10

LEAKING TEMPERATURE & PRESSURE RELIEF
VALVE

HOT WATER ODORS (CAUTION:
UNAUTHORIZED REMOVAL OF THE ANODE(S)
WILL VOID THE WARRANTY. FOR FURTHER
INFORMATION, CONTACT YOUR DEALER.)

NOT ENOUGH OR NO HOT WATER

WATER TOO HOT

WATER HEATER SOUNDS

Содержание AOSRE50100

Страница 1: ...yxiation serious personal injury or death Do not cover the temperature pressure relief T P valve Do not cover the instruction manual Keep it on the side of the water heater or nearby for future refere...

Страница 2: ...INLET LINE AS REQUIRED BY LOCAL CODES INSTALL SUITABLE DRAIN PANS UNDER HEATERS TO PREVENT DAMAGE DUE TO LEAKAGE REFER TO WATER HEATER LOCATION ON PAGE 3 INSTALL THERMAL EXPANSION TANK OR DEVICE IF W...

Страница 3: ...ealant is used to prevent leakage TEMPERATURE AND PRESSURE RELIEF VALVE ANEWTEMPERATUREANDPRESSURERELIEFVALVECOMPLYING WITHTHESTANDARDFORRELIEFVALVESFORHOTWATERSUPPLY SYSTEMS ANSIZ21 22MUSTBEINSTALLED...

Страница 4: ...ME CLOCK OR OFF PEAK METER NOTE Some Lower Hi Temp Limit Switches may have 4 terminals Use only the 2 terminals on left A 3 2 WIRE 240 VOLT POWER SUPPLY NON SIMULTANEOUS OPERATION WIRING FOR 3 WIRE LE...

Страница 5: ...angular degrees will result in a 10 degree Fahrenheit change in water temperature TEMPERATURE ADJUSTMENT To change the temperature setting DANGER 1 Turn offtheheaterelectricalsupply Donotattempttoadj...

Страница 6: ...ubmerged rod sacrifices itself to protect the tank Instead of corroding the tank water ions attack and eat away the anode rod This does not affect the water s taste or color The rod must be maintained...

Страница 7: ...eater FIGURE7 2 Using the remaining two sheet metal screws provided secure the bottom mounting bracket to the bottom of the water heater FIGURE8 3 Determine the location on the wall and then the heigh...

Страница 8: ...CAL COMPONENTS OPTIONAL CORD SET WIRING 120 VOLT AND 240 VOLT There may be a cord set supplied with the water heater at the time of manufacture If not one can be ordered through the Parts Department s...

Страница 9: ...onship between degrees of angular rotation and the corresponding changeintemperature Thusrotatingthetemperatureadjustmentindicator 30 angular degrees will result in a 10 degree Fahrenheit change in wa...

Страница 10: ...e element discard gasket and clean thread areas Apply non hardening Permatex No 2 to thread areas install new gasket and screw element into fitting until it seats Tighten 1 2 to 3 4 turn with wrench b...

Страница 11: ...the water heater or any part thereof including freezing fire floods or lightning any misuse abuse or alteration of it any operation of it in a modified form or any attempt to repair tank leaks or part...

Страница 12: ...12 5621 W 115TH STREET ALSIP ILLINOIS 60803 Phone 1 800 433 2545 Fax 1 800 433 2515 www hotwater com email parts hotwater com...

Отзывы: