background image

5

  OPERATION

 CAUTION

NEVER OPERATE THE HEATER WITH THE COLD WATER INLET VALVE
CLOSED OR WITHOUT FILLING WITH WATER PER THE FILLING
INSTRUCTIONS.  FAILURE TO DO SO WILL CAUSE DAMAGE AND CAN
VOID ELEMENT WARRANTY.

FILLING

1. Close the water heater drain valve.  (Turn clockwise 

 ).

2. Open a nearby hot water faucet to permit air to escape.
3. Fully open the cold water inlet valve, filling the heater and piping.
4. Close the hot water faucet when water flows.
5. Turn the water heater electrical switch on.

TEMPERATURE REGULATION

DANGER

THE WATER HEATER IS EQUIPPED WITH AN ADJUSTABLE THERMOSTAT
OR THERMOSTATS  TO CONTROL WATER TEMPERATURE.  HOT WATER
AT TEMPERATURES DESIRED FOR AUTOMATIC DISHWASHER AND
LAUNDRY USE CAN CAUSE SCALDS RESULTING IN SERIOUS PERSONAL
INJURY AND/OR DEATH.  THE TEMPERATURE AT WHICH INJURY OCCURS
VARIES WITH THE PERSON’S AGE AND TIME OF EXPOSURE.  THE
SLOWER RESPONSE TIME OF CHILDREN, AGED OR DISABLED PERSONS
INCREASES THE HAZARD TO THEM.  NEVER ALLOW SMALL CHILDREN
TO USE A HOT WATER TAP, OR TO DRAW THEIR OWN BATH WATER.
NEVER LEAVE A CHILD OR DISABLED PERSON UNATTENDED IN A
BATHTUB OR SHOWER.

It is recommended that lower water temperatures be used to avoid the
risk of scalding.  It is further recommended, in all cases, that the water
temperature thermostats (See Figure 4) be set for the lowest temperature
which satisfies your hot water needs.  This will also provide the most
energy efficient operation of the water heater. Thermostat(s) are factory
set at 120°F (49°C) unless specified differently by state requirements.

KEEPING THE THERMOSTAT SETTING AT 120°F WILL REDUCE THE RISK
OF SCALDS.

Figure 4 shows the approximate time-to-burn relationship for normal
adult skin.  The thermostats on your water heater have a linear
relationship between degrees of angular rotation and the corresponding
change in temperature.  Thus rotating the temperature adjustment indicator
40 angular degrees will result in a 10 degree Fahrenheit change in water
temperature.

TEMPERATURE ADJUSTMENT

To change the temperature setting:

DANGER

1. Turn off the heater electrical supply. Do not attempt to adjust thermostat

with power on.

2. Remove the thermostat access panels and covers from the

thermostats. Do not remove the plastic personnel protectors covering
the thermostats.

3. Using a flat tip screwdriver, rotate the adjusting knob to the desired

temperature setting.

4. Replace the covers and access panels, and turn on heater electrical

supply.

       

TEMPERATURE SETTINGS

HOT - Is a thermostat setting of approximately 120° F,

which will supply hot water at the most
economical temperatures..

A - Is a thermostat setting of approximately 130° F.

B - Is a thermostat setting of approximately 140° F.

C - Is a thermostat setting of approximately 150° F.

VERY HOT - Is a thermostat setting of approximately 160° F.

It is recommended that the dial be set lower
whenever possible.

Temperature

Time to Produce 2nd & 3rd

Setting

Degree Burns on Adult Skin

170° F

Nearly instantaneous

160° F

About 1/2 second

150° F

About 1-1/2 seconds

140° F

Less than 5 seconds

130° F

About 30 seconds

125° F

About 2 minutes

120° F

More than 5 minutes

FIGURE  4

Valves for reducing point-of-use temperature by mixing cold and hot
water are available (see Figure 5). Also available are inexpensive devices
that attach to faucets to limit hot water temperatures. Contact a licensed
plumber or the local plumbing authority.

A non-adjustable high temperature limit control operates before steam
temperatures are reached.  The high limit is in the same area as the upper
thermostat and must be reset manually when it operates.

BECAUSE THE

HIGH LIMIT OPERATES ONLY WHEN ABNORMALLY HIGH WATER
TEMPERATURES ARE PRESENT, IT IS IMPORTANT THAT A QUALIFIED
SERVICE AGENT BE CONTACTED TO DETERMINE THE REASON FOR
OPERATION BEFORE RESETTING.

FIGURE  5

UPPER THERMOSTAT

(DUAL ELEMENT

MODELS ONLY)

ADJUSTABLE

LOWER

THERMOSTAT

(FOR DUAL

ELEMENT MODELS)

ADJUSTABLE

LOWER

THERMOSTAT

WITH HIGH LIMIT

Содержание AOSRE50100

Страница 1: ...yxiation serious personal injury or death Do not cover the temperature pressure relief T P valve Do not cover the instruction manual Keep it on the side of the water heater or nearby for future refere...

Страница 2: ...INLET LINE AS REQUIRED BY LOCAL CODES INSTALL SUITABLE DRAIN PANS UNDER HEATERS TO PREVENT DAMAGE DUE TO LEAKAGE REFER TO WATER HEATER LOCATION ON PAGE 3 INSTALL THERMAL EXPANSION TANK OR DEVICE IF W...

Страница 3: ...ealant is used to prevent leakage TEMPERATURE AND PRESSURE RELIEF VALVE ANEWTEMPERATUREANDPRESSURERELIEFVALVECOMPLYING WITHTHESTANDARDFORRELIEFVALVESFORHOTWATERSUPPLY SYSTEMS ANSIZ21 22MUSTBEINSTALLED...

Страница 4: ...ME CLOCK OR OFF PEAK METER NOTE Some Lower Hi Temp Limit Switches may have 4 terminals Use only the 2 terminals on left A 3 2 WIRE 240 VOLT POWER SUPPLY NON SIMULTANEOUS OPERATION WIRING FOR 3 WIRE LE...

Страница 5: ...angular degrees will result in a 10 degree Fahrenheit change in water temperature TEMPERATURE ADJUSTMENT To change the temperature setting DANGER 1 Turn offtheheaterelectricalsupply Donotattempttoadj...

Страница 6: ...ubmerged rod sacrifices itself to protect the tank Instead of corroding the tank water ions attack and eat away the anode rod This does not affect the water s taste or color The rod must be maintained...

Страница 7: ...eater FIGURE7 2 Using the remaining two sheet metal screws provided secure the bottom mounting bracket to the bottom of the water heater FIGURE8 3 Determine the location on the wall and then the heigh...

Страница 8: ...CAL COMPONENTS OPTIONAL CORD SET WIRING 120 VOLT AND 240 VOLT There may be a cord set supplied with the water heater at the time of manufacture If not one can be ordered through the Parts Department s...

Страница 9: ...onship between degrees of angular rotation and the corresponding changeintemperature Thusrotatingthetemperatureadjustmentindicator 30 angular degrees will result in a 10 degree Fahrenheit change in wa...

Страница 10: ...e element discard gasket and clean thread areas Apply non hardening Permatex No 2 to thread areas install new gasket and screw element into fitting until it seats Tighten 1 2 to 3 4 turn with wrench b...

Страница 11: ...the water heater or any part thereof including freezing fire floods or lightning any misuse abuse or alteration of it any operation of it in a modified form or any attempt to repair tank leaks or part...

Страница 12: ...12 5621 W 115TH STREET ALSIP ILLINOIS 60803 Phone 1 800 433 2545 Fax 1 800 433 2515 www hotwater com email parts hotwater com...

Отзывы: