Installation
32
Instruction manual ADMR
3
is
Terminal block
3.10.3
Connecting the mains power
The appliance is supplied without a power cable and isolator.
Note
In order to receive electrical power, the appliance has to be connected to the
mains power by means of a permanent electrical connection. A double-pole
isolator with a contact gap of at least 3 mm must be fitted between this
permanent connection and the appliance. The power cable must have cores of
at least 3 x 1.0 mm
2
.
Warning
Leave the appliance isolated until you are ready to start it up.
1. Feed the power cable through the metric strain relief to the top side of the
control column.
2. Connect the earth ( ), live (L
1
) and neutral (N) of the power cable to
terminals 1 through 3 in the connector block as stated in the table.
3. Turn the strain relief tight to clamp the lead.
4. If you do not need to make any more connections, fit the protective cover
onto the control column.
5. Connect the power cable to the isolator.
Mains power
Top to bottom
circulation
pump
Continuous
pump
Unused
L1
N
L2
N
L3
N
-
-
-
1
2
3
4
5
6
7
8
9
10
11
12
Tank ON
Flue gas safety
S1
S2
X1
X2
X1
X2
X3
X4
13
14
15
16
17
18
Alarm Out
Relay
power
Unu
sed
Flue damper
X!
X2
L4
N
-
L5
N
L6
X1
X2
19
20
21
22
23
24
25
26
27
28
29
30
Isolating transformer
Primary
Secondary
N
L7
N
L8
31
32
33
34
35
36
Содержание ADMR-115
Страница 4: ...4 Instruction manual ADMR gis...
Страница 8: ...Table of contents 8 Instruction manual ADMR...
Страница 12: ...Introduction 12 Instruction manual ADMR 1 gis...
Страница 38: ...Installation 38 Instruction manual ADMR 3 is...
Страница 56: ...Shutting down 56 Instruction manual ADMR 10 gis...
Страница 64: ...Main menu 64 Instruction manual ADMR 11 gis...
Страница 78: ...is Instruction manual ADMR 78...
Страница 80: ...Maintenance frequency 80 Instruction manual ADMR 14 is...
Страница 86: ...Performing maintenance 86 Instruction manual ADMR 15 s...
Страница 94: ...Appendices 94 Instruction manual ADMR 17 is...
Страница 96: ...Instruction manual ADMR 96...