Instruction manual ADMR
29
is
3.9.3
Fitting the flue damper
The following parts can be found in the separate package for the flue damper,
supplied with the appliance: the complete assembled flue damper (1), a
mounting plate (2) with hole for the flue damper shaft, and fastening screws.
You may fit the flue damper in either the left or the right hand side of the draught
diverter.
Flue damper
1. Take the flue damper (1) out of the packaging.
2. There are two cover plates on the draught diverter, one on each side.
Unscrew these.
3. Fit the mounting plate (2) with shaft hole, supplied with the flue damper, on
one side of the draught diverter.
4. Slide the flue damper, as shown in the figure, into the other opening in
Note
See
Electrical connection
for the flue damper electrical connections.
Legend
1 flue damper
2 mounting plate
1
2
IMD-0124 R1