MaiNteNaNCe (continued)
Monthly: bun temperature test
Note: the minimum temperature allowed is 150°
f (65.6º C). if this temperature is not achieved con-
tact your authorized service agency.
tools Required:
Pyrometer/Needle probe attachment,
four 8 oz. coffee cups stacked together, plus one lid
or four 2 oz coffee cups plus one lid.
. Turn the Rocker Switch (power On/Off) to ON and
allow the unit to preheat for 30 minutes.
2. Toast 3 regular buns (to be used with the 8oz.
cup stack) or 4 regular buns (to be used with the
2 oz. cup stack).
3. Immediately stuff the buns into the stacked cups
and tightly apply the lid. Wait for 0 minutes.
4. Insert the needle probe attachment of the
pyrometer through the lid several times.
Note the maximum temperature.
Monthly: Replace Release sheet.
every three Months: Replace belt Wraps,
Clean and Measure Conveyor belt Chains,
Check Roller tensioners, and Check
temperature of bun landing area.
Remove the Belt Wraps & Release Sheet.
. Turn the unit OFF, unplug the toaster, and allow it
to cool down.
2. Remove the Bun Feeder, Bun Chute, and change
the Bun Thickness Compression Controls to
“F & 6” (Figure 2a and 2b).
3. Remove and discard the black Release Sheet.
4. Open the Front (heel/Club) Conveyor Cover and
rotate the Belt Wrap so its flap is in the middle
(top to bottom) of the conveyor. Pull the hinge
pin out of the Belt Wrap and then remove and
discard this Belt Wrap. Repeat this process on
the Rear (Crown) side.
Clean the Conveyor belt Chains
. Spray
Mcd© all-purpose super Concentrate
(hCs)
on a clean, dry, towel and wipe the sur-
face of the Rear (Crown) Conveyor Belt Chain
links firmly from side to side and top to bottom.
Immediately repeat this procedure with a clean,
dry, towel dampened with
KaYQUat™ sanitizer
(hCs)
solution and repeat this procedure on the
Front (heel/Club) Conveyor Belt chain.
2. Close the Conveyor Cover(s), plug in the power
cord, turn on the unit, count to ten (0) seconds
for MFG# 920606, count thirteen (3) seconds
for MFG# 92066. For MFG# 920607, 608,
63, 65, 624, & 626 count to seventeen (7)
seconds. Next, turn the unit OFF and unplug the
power cord.
Note: Refer to figure 2 in the operation section of
this Manual.
3. Open the Conveyor Cover(s) and repeat Step
to clean the other half of both the Front (heel/
Club) and Rear (Crown) Conveyor Belt Chains.