![A.J.Antunes 9100320 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/a-j-antunes/9100320/9100320_manual_447193015.webp)
15
P/N 1010751 Rev. G 01/08
McDonald’s
Multi-purpose steaMer Mps-250
diaGNostiCs (continued)
UP
DOWN
PROGRAM SINGLE SHOT
1
2
3
4
ERR
err
(Error) will be displayed when there are program-
ming parameter errors. If this message appears, you
may have to clear the current parameters.
To clear the unit’s current programming and reset the
unit to its’ factory default settings:
1. Turn the unit off.
2. Push the
start/stoP
and
doWN arroW
keys simultaneously and, while turning the unit
back on continue to hold them until you hear the
unit BEEP (and then stops).
3. Check the Display.
• If the Display shows “ERR” again, contact
Roundup for technical assistance.
• If the Display appears normal, try both a
single shot and factory default timed cycles
before attempting to reprogram the unit.
Review the Programming section of this manual (Page
8) and then program the Menu Channel Buttons
according to your cooking requirements.
The TEMP Display indicates that the control cabinet
temperature has exceeded 155ºF (68ºC). If this occurs,
the unit must be turned off for at least 20 minutes so
that it can cool off and reset.
If this condition reoccurs, contact your Authorized
Service Agency or Roundup Technical Assistance.
The control board monitors the control cabinet ambient
temperature and records whatever its highest tempera-
ture has been. Your service technician could find such
information very useful when troubleshooting the unit.
To determine what the control cabinet’s highest tem-
perature has been since it was last reset:
1. Turn the unit off.
2. Turn the unit back On while pressing both the
uP
and
doWN arroWs
at the same time.
3. Read the highest control cabinet temperature
recorded on the display and release the arrow
keys.
4. Turn the unit off again to preserve this record.
To clear/reset this record, press both the
uP
and
doWN arroWs
and
ProGraM
button simultane-
ously (before turning the unit off) and the display will
show 33ºF - indicating that the record has been cleared
- and then turn the unit off.
UP
DOWN
PROGRAM SINGLE SHOT
1
2
3
4
TEMP
teMP
indicates the control cabinet temperature has
exceeded 155°F (68°C) causing the unit to shut down.
UP
DOWN
PROGRAM SINGLE SHOT
1
2
3
4
POWER
00:10
To change the Setpoint temperature, press and hold
the
uP
and
doWN
arrows simultaneously for three
seconds. Then, raise or lower the temperature by
Pressing the
uP
or
doWN
arrows. Minimum tempera-
tures should be 375°F (191° C).
UP
DOWN
PROGRAM SINGLE SHOT
1
2
3
4
POWER
00:10
To check the GENERATOR temperature, press and
hold the
uP
arrow
. The display will read the set tem-
perature.