background image

3

E

n

g

lis

h

E

n

g

lis

h

4

CONTROLS AND FUNCTIONS

1)

"MAINS FUSE" FUSE CARRIER

Mains fuse housing.

2)

“FULL RANGE MAINS INPUT" POWER SOCKET

For connecting the power cable provided.
The connector used for mains connection is a POWER CON® (blue)

3)

“LINK” RELAUNCH POWER SOCKET

For relaunching the mains power. The output is connected in parallel with input (2) 
and can be used to power another amplified speaker. 
The connector uses a POWER CON® (grey)

4)

COOLING GRILLE

These grilles permit cooling the amplifier during operation. 
Do not block accesses and clean the grilles whenever necessary to ensure correct 
air circulation.

5)

" BALANCED MAIN INPUT” INPUT CONNECTOR

Balanced input at line level (0 dBu).
It is able to accept “XLR” sockets. 

6)

"LINK” OUTPUT CONNECTOR

The “XLR” connector connected in parallel with input (5) can be used to send the 
input audio signal to another amplified speaker.

7)

”BALANCED X-OVER   OUTPUT” OUTPUT CONNECTOR

Internal crossover balanced output. The signal from this output can be sent to any 
other amplified speaker.
The crossover frequency can be selected by means of the “SUB X-OVER” switch (8).

8) “SUB 

X-OVER” SWITCH

This switch permits selection of crossover frequency between the sub woofer and 
the speakers connected to the 

”BALANCED X-OVER   OUTPUT” connector.

The crossing frequency is selected to 90Hz or 120Hz with a slope of 24dB/oct.
The frequency choice depends to the sound reproduction desire.   

9)

“SUB PHASE ” SWITCH

This switch permits 180° rotation of the audio signal reproduced by subwoofer.
Rotation makes for easier optimization of low-frequency reproduction even in the 
most difficult installation situations. After completing installation, reproduce a piece 
of music and adjust the switch to obtain the best low-frequency sound.

10)

“ON” INDICATOR LIGHT 

The “ON” indicator light comes on green to indicate the amplifier is switched on and it 
is working properly. 

11)

“SGN” INDICATOR LIGHT

This indicator comes on green to indicate the presence of the audio signal (at a level 
of -20dB). 

12)

“LIM” INDICATOR LIGHT

This indicator comes on red to indicate that the internal limiter circuit has tripped. 
This prevents amplifier distortion and protects the speakers against overloads.
It is lights for a few seconds during the switching on.

13)

“SUB WOOFER LEVEL” INPUT SENSITIVITY CONTROL

This control regulates the sensitivity of the signal at amplifier input. 
This control does not affect the “LINK” and “BALANCED X-OVER   OUTPUT” output 
levels

14)

DIGITAL DELAY “SDD - SUBWOOFER DIGITAL DELAY” OPTION

The DVA S10dp loudspeaker can be equipped with a delay module (SDD - 
SUBWOOFER DIGITAL DELAY) that allows to delay the sound signal reproduced 
by the subwoofer.   

This circuit allows sound-alignment between line array and sub 

by balancing the various positions. 
The circuit also includes a balanced “XLR” output that sends the delayed audio 

TECHNICAL SPECIFICATION

System

Active

Type of amplifier

Digital - Class D   (DIGIPRO ) 

RMS power

1000 W

Musical power

2000 W

Frequency responce   +/-3dB

40-150Hz

Crossover

 90 - 120Hz (24dB/oct) selecting

Sound pressure (SPL) 

136dB peak

 

Woofer

1 x woofer 18” -  4” voice coil 
Neodymium or Ceramic 

Input sensitivity   nominal

0 dBu

Impedance input     Balanced

20Kohm

      Unbalanced

10Kohm

Speaker shape

rectangular

Dimension [WxHxD]

515x640x770mm 

Weight

Neodymium 42Kg - Ceramic 48Kg

 Weight 

Neodymium 47,2Kg - Ceramic 53,2kg

®

Full-range with PFC,   100-240Vac,   50-60Hz

(with SRK10 Fly kit)

Power supply

signal to other subwoofers. By using a single delay module it is possible to delay 
several subwoofers at the same time.
This module can also be used to create cardioid configuration systems. The cardioid 
configuration provides a remarkable attenuation of the low frequencies radiated by 
the rear side of the   subs, without changing the direct radiated signal on the fronside. 
This configuration needs at least 3 subwoofers (two with front radiation and one with 
rear radiation equipped with SDD module). See appendix for more details. 

EMI CLASSIFICATION

According to the standards EN 55103 this equipment is designed and suitable to operate in E3 
(or lower E2, E1) Electromagnetic environments.

220-240V~ MAX 15A
100-120V~ MAX 10A 

BALANCED
MAIN INPUT

LINK

BALANCED
X-OVER 
OUTPUT

+10

+4

SUB-WOOFER

LEVEL

90Hz

120Hz


180°

ON

SGN LIM

SUB

PHASE

SUB

XOVER

FULL RANGE MAINS INPUT
      100-240V~   50-60Hz

1250W MAX

MAINS FUSE

220-240V~ (

 

T5A  250V

 

)

100-120V~ (T10A 250V)

ACTIVE P.F.C.

Made in Italy

S

E

R

IA

L

 N

.

“CAUTION”

TO PREVENT ELECTRICAL SHOCK

DO NOT REMOVE COVER

“AVIS”

RISQUE DE CHOCH ELECTRIQUE

NE PAS OUVRIR

LINK

BB

dd

TECHNOLOGIES

TECHNOLOGIES

digital power

digital power

1

2

3

1 = GND
2 = HOT
3 = COLD

1

2

3

1

2

3

S

S 0

0

digital power

digital power

8

0dB

PUSH

SUBWOOFER DIGITAL DELAY

D

D

B

d

TECHNOLOGIES

TECHNOLOGIES

S

S

OPTIONAL  CARD

D

D

5

6

7

9

11

13

12

10

8

4

1

2

3

4

4

4

14

NEODYMIUM

CERAMIC

Содержание S10DP

Страница 1: ...9870 Fax 39 051 969725 Internet www dbtechnologies com E mail info dbtechnologies aeb com Made in Italy COD 420120164 Rev 5 digital power R R S S 0 0 ACTIVE SUBWOOFER MANUALE d USO Sezione 1 USER MANUAL Section 1 BEDIENUNGSANLEITUNG Abschnitt 1 CARACTERISTIQUES TECHNIQUES Section 1 ...

Страница 2: ...asi diffusore amplificato La frequenza di taglio è selezionabile tramite il selettore SUB X OVER 8 8 SELETTORE SUB X OVER Il selettore permette di modificare l incrocio frequenza di taglio o crossover tra il subwoofer ed il diffusore ad esso collegato tramite l uscita BALANCED X OVER OUTPUT L incrocio è settabile a 90Hz oppure 120Hz con una pendenza di 24dB oct La scelta del taglio è legata dal ti...

Страница 3: ...ROL This control regulates the sensitivity of the signal at amplifier input This control does not affect the LINK and BALANCED X OVER OUTPUT output levels 14 DIGITALDELAY SDD SUBWOOFER DIGITALDELAY OPTION The DVA S10dp loudspeaker can be equipped with a delay module SDD SUBWOOFER DIGITAL DELAY that allows to delay the sound signal reproduced by the subwoofer This circuit allows sound alignment bet...

Страница 4: ...ndert und die Lautsprecher gegen Überlast schützt Während desAnschaltens leuchtet die LED für ein paar Sekunden 13 EMPFINDLICHKEITSREGLER EINGANG SUBWOOFER LEVEL Dieser Regler dient zum Einstellen der Eingangs Empfindlichkeit des Verstärkers Diese Regelung beeinflusst nicht den Ausgangspegel BALANCED LINK und X OVER BALANCED OUTPUT 14 OPTION DIGITAL DELAY SDD SUBWOOFER DIGITALDELAY Der DVA S10dp k...

Страница 5: ...ite la distorsion de l amplificateur et protège les haut parleurs des surcharges Il s éclaire également pendant quelques secondes lorsque l amplificateur est allumé 13 CONTRÔLE SENSIBILITÉ ENTRÉE SUBWOOFER LEVEL Ce contrôle règle la sensibilité du signal en entrée à l amplificateur Ce contrôle n influence pas le niveau de la sortie LINK et BALANCED X OVER OUTPUT 14 OPTION DIGITAL DELAY SDD SUBWOOF...

Страница 6: ...pezionato da personale qualificato ed i possibili difetti debbano essere eliminati prima della consegna all utente finale La normativa 41 VBG 9a richiede che l equipaggiamento del carico portante debba essere soggetto a una manutenzione non ordinaria successivamente a danni riparazioni e altri incidenti che possono avere effetto sulla capacità del carico portante Attenzione Le normative sulla sicu...

Страница 7: ...ects be eliminated prior to initial commissioning by the recipient The safety regulation 41 VBG 9a requires that load carrying equipment be subjected to a non routine inspection following damage repair work and other incidents that can affect load carrying capacity Warning The safety regulations might be different in other countries Please check with your national safety authority the valid regula...

Страница 8: ...richtungen nach Schadensfällen oder anderen Vorkommnissen welche die Tragfähigkeit beeinflussen können und nach Instandsetzungsarbeiten einer außerordentlichen Prüfung unterzogen werden Warnung Sicherheits Vorschriften kann sich je nach dem Bestimmungsland Überprüfen Sie die geltenden Vorschriften in Einklang mit den Vorschriften über die Sicherheit in dem Land Deutsch Deutsch Deutsch Deutsch Deut...

Страница 9: ... possibles défauts doivent être éliminés avant la livraison à l usager final La norme sur la sécurité 41 VBG 9a demande que l équipement du porte charge doit être sujet à une manutention non ordinaire suite à des dommages réparations et autres incidents qui peuvent avoir effet sur la capacité du porte charge Attention Les normes sur la sécurité peuvent être différentes en fonction du pays de desti...

Страница 10: ...l Array T 4 COLLEGAMENTI CABLE CONNECTIONS VERKABELUNG CABLAGE SCHEMA A BLOCCHI BLOCK DIAGRAM BLOCKSCHALTBILD DIAGRAMA EM BLOQURES BALANCED MAIN INPUT LINK BALANCED X OVER OUTPUT 90Hz 120Hz SUB X OVER switch Digital Delay Optional WOOFER 18 LIMITER SUB PHASE switch Phase 180 Phase 0 SIGNAL 20dB CONTROL CIRCUITS L N MAINS INPUT MAINS FUSE INPUT SENS READY L N MAINS INPUT LINK BALANCED MAIN INPUT LI...

Страница 11: ...19 20 INSTALLAZIONE INSTALLATION INSTALLATIONEN INSTALLATIONS In appoggio impilato Groundstack stacked In appoggio Groundstack In appoggio con flybar opzione DRK 10 Groundstack with flybar DRK 10 option ...

Страница 12: ...it staffe opzione SRK 10 e flybar opzione DRK 10 Hang with stirrups kit SRK 10 option and flybar DRK 10 option Kit staffe opzione SRK 10 Kit stirrups SRK 10 option In appoggio con kit staffe Groundstack with kit stirrups ...

Страница 13: ...nd adaptor Set di 4 ruote opzione DWK 20 Set of 4 wheels DWK 20 option In appoggio a pavimento con supporto asta provvisto di piedi Groundstack to floor with stand adaptor with feet Per supporto asta Stand adaptor Opzione DSA 4 DSA 4 Option In appoggio Floor stack ...

Страница 14: ...e il delay a 4 5msec Set delay to 4 5msec mSec DELAY SET UP 0 5 4 3 1 2 6 7 8 9 0 5 4 3 1 2 6 7 8 9 0 50 40 30 10 20 60 70 80 90 Delay ms espresso in millisecondi GAP m espresso in metri Velocità suono 344 m s BALANCED MAIN INPUT LINK BALANCED X OVER OUTPUT 10 4 SUB WOOFER LEVEL 90Hz 120Hz 0 180 ON SGN LIM SUB PHASE SUB XOVER B B d d TECHNOLOGIES TECHNOLOGIES 1 2 3 1 GND 2 HOT 3 COLD 1 2 3 1 2 3 S...

Отзывы: