4.
RF
Modem
Configuration
4.1. Automatic DIP Switch Configurations
Each time the RF modem is powered-on, AT commands are sent to the on-board module as dic-
tated by the positions of the DIP switches. DIP switch configurations are sent automatically during
the power-on sequence and affect modem parameter values as shown in the table below.
Figure
4
‐
01. RF
Modem
DIP
Switches
IMPORTANT: To avoid overwriting previously stored custom configurations (due to the automatic con-
figurations that take place each time the RF modem is powered-on), it is necessary to disable a pro-
cessor located inside the modem.
To disable the processor, turn switches 5 and 6 ON (up). When switches 5 and 6 are ON, only the CS
command is sent [refer to table below].
Note:
The
results
of
SW
2,
5
&
6
ON
and
SW
5
&
6
ON
are
the
same.
Table
4
‐
01. Power
‐
up
Options
‐
Commands
sent
as
result
of
DIP
Switch
Settings
(SW
=
DIP
Switch)
Switches
Condition
Behavior
Commands Sent During Power-up
Switches 1 & 2
(Restore Defaults /
Serial Interfacing)
If SW1 & SW2 are
ON (up)
Restore Defaults
ATRE
ATWR
(Restore Defaults)
(Write defaults to non-volatile memory)
If SW1 is ON (up)
RS-232 Operation ATCS 0
(RS-232, CTS flow control)
If SW1 is OFF (down)
RS-485/422
Operation
ATCS 3
(RS-485 or RS-422 Operation)
Switches 5 & 6
(TX/RX Modes)
If SW5 & SW6 are
OFF (down)
Multipoint Base
ATMY 0
ATDT FFFF
ATMT 3
(Source Address)
(Destination Address)
(Multi-Transmit option)
If SW5 is OFF (down)
& SW6 is ON (up)
Multipoint Remote
ATAM
ATDT 0
ATMT 0
ATRR A
(Auto-set MY, MY = unique)
(Destination Address)
(Multi-Transmit option)
(Retries)
If SW5 is ON (up) &
SW6 is OFF (down)
Point-to-Point
ATAM
ATDT FFFF
ATMT 3
(Auto-set MY, MY = unique)
(Destination Address)
(Multi-Transmit option)
If SW5 is ON (up) &
SW6 is ON (up)
User Defined
Processor is disabled and AT Commands are not sent to
the modem (except for CS command as shown below.)
Table
4
‐
02. User
Defined
Mode
(Switches
5
and
6
are
ON
(up))
Only DIP Switches ON (up)
Condition
Command Sent During Power-up
SW1, SW5 and SW6
If CS = 0, 1, 2 or 4
CS parameter remains the same
If CS = 3
ATCS 0
(RS-232 operation, CTS flow control)
SW2, SW5 and SW6
If CS = 2
ATCS 2
(GPO1 high)
If CS = 0, 1, 3 or 4
ATCS 3
(RS-485/422 Operation)
SW5 and SW6 only
If CS = 2
ATCS 2
(GPO1 high)
If CS = 0, 1, 3 or 4
ATCS 3
(RS-485/422 Operation)