2.3. RS-485 (4-wire) & RS-422 Operation
2.3.1. DIP Switch Settings and Pin Signals
2.3.2. Wiring Diagrams
Figure
2
‐
13. XTend
RF
Modem
in
an
RS
‐
485
(4
‐
wire)
environment
Table
2
‐
03. RS
‐
485/422
(4
‐
wire)
Signals
and
their
implementations
on
the
XTend
RF
Modem
DB-9 Pin
RS-485/422
Name
Description
Implementation
2
T- (TA)
Transmit Negative
Data Line
Serial data sent from the RF modem
3
R- (RA)
Receive Negative
Data Line
Serial data received by the RF modem
5
GND
Signal Ground
Ground
7
R+ (RB)
Receive Positive
Data Line
Serial data received by the RF modem
8
T+ (TB)
Transmit Positive
Data Line
Serial data sent from the RF modem
9
PWR
Power
Optional power input that is connected internally
to the front power connector
1, 4, 6
not used
Figure
2
‐
10. RS
‐
485
(2
‐
wire)
Half
‐
duplex
DIP
Switch
Settings
Figure
2
‐
11. Pins
used
on
the
female
RS
‐
232
(DB
‐
9)
Serial
Connector
Figure
2
‐
12. RS
‐
485
(2
‐
wire)
w/
Termination
(optional)
Termination
is
the
120
Ω
resistor
between
T+
and
T
‐
.
DIP
Switch
settings
are
read
and
applied
only
while
powering
‐
on.