18/06/2022 YAV90132 / YAV90133
10.
HARDWARE SPECIFICATIONS
Operation parameters
Property
Min.
Typ.
Max.
Units
•
Control Voltage
18
24
32
V
•
Operating current @24VDC and 25ºC
390
mA
•
CAN Bus operation speed
50
250
kbps
•
Ambient operating temperature
5
65
degC
•
Power Dissipation (TA = 25 ºC)
3
W
Operation specifications
Switching specifications
Property
Min.
Typ.
Max.
Units
•
Rated current
2
A
•
Maximum switching voltage AC
400
V
Switching specifications
YAV90132 Relays contact specifications
Property
Min.
Typ.
Max.
Units
•
Maximum switching power AC
1250
VA
•
Mechanical endurance
15x10^6
Cycles
•
Electrical endurance
>100000
Cycles
•
Maximum electrical operation frequency
1800
Cycles/h
•
Contact resistance
<50
mOhm
•
Operate time
5
ms
•
Release time
2
ms
•
Bounce time
1
ms
YAV90132 Relay contact specifications
YAV90133 Relays contact specifications
Property
Min.
Typ.
Max.
Units
•
Maximum switching power AC
60
VA
•
Mechanical endurance
10^8
Cycles
•
Electrical endurance
>100000
Cycles
•
Minimum switching voltage
100
µV
•
Contact resistance
<50
mOhm
•
Operate time
1
3
ms
•
Release time
3
5
ms
•
Bounce time
1
5
ms
•
Contact material
PdRu+Au
YAV90133 Relay contact specifications