background image

Pag 6 | 13   

www.6tlengineering.com

   18/06/2022   YAV90132 / YAV90133   

 
 

6. 

PINOUT (FRONT) 

 

 

Module function 

Receiver Pos. # 

 

 

YAV90132: 32 SPDT relays 

I.T.A. Module P/N 

510 108 126 

I.T.A. contact P/N 

610 110 108 

Pin 

Description 

Pin 

Description

 

Pin 

Description

 

0V 

33 

CAN L 

65 

+24V 

34 

CAN H 

66 

NC relay K1 

35 

67 

NO relay K1 

NC relay K2

 

36 

COMMON relay K1 

68 

NO relay K2

 

NC relay K3

 

37 

COMMON relay K2

 

69 

NO relay K3

 

NC relay K4

 

38 

COMMON relay K3

 

70 

NO relay K4

 

NC relay K5

 

39 

COMMON relay K4

 

71 

NO relay K5

 

NC relay K6

 

40 

COMMON relay K5

 

72 

NO relay K6

 

NC relay K7

 

41 

COMMON relay K6

 

73 

NO relay K7

 

10 

NC relay K8

 

42 

COMMON relay K7

 

74 

NO relay K8

 

11 

NC relay K9

 

43 

COMMON relay K8

 

75 

NO relay K9

 

12 

NC relay K10

 

44 

COMMON relay K9

 

76 

NO relay K10

 

13 

NC relay K11

 

45 

COMMON relay K10

 

77 

NO relay K11

 

14 

NC relay K12

 

46 

COMMON relay K11

 

78 

NO relay K12

 

15 

NC relay K13

 

47 

COMMON relay K12

 

79 

NO relay K13

 

16 

NC relay K14

 

48 

COMMON relay K13

 

80 

NO relay K14

 

17 

NC relay K15

 

49 

COMMON relay K14

 

81 

NO relay K15

 

18 

NC relay K16

 

50 

COMMON relay K15

 

82 

NO relay K16

 

19 

NC relay K17

 

51 

COMMON relay K16

 

83 

NO relay K17

 

20 

NC relay K18

 

52 

COMMON relay K17

 

84 

NO relay K18

 

21 

NC relay K19

 

53 

COMMON relay K18

 

85 

NO relay K19

 

22 

NC relay K20

 

54 

COMMON relay K19

 

86 

NO relay K20

 

23 

NC relay K21

 

55 

COMMON relay K20

 

87 

NO relay K21

 

24 

NC relay K22

 

56 

COMMON relay K21

 

88 

NO relay K22

 

25 

NC relay K23

 

57 

COMMON relay K22

 

89 

NO relay K23

 

26 

NC relay K24

 

58 

COMMON relay K23

 

90 

NO relay K24

 

27 

NC relay K25

 

59 

COMMON relay K24

 

91 

NO relay K25

 

28 

NC relay K26

 

60 

COMMON relay K25

 

92 

NO relay K26

 

29 

NC relay K27

 

61 

COMMON relay K26

 

93 

NO relay K27

 

30 

NC relay K28

 

62 

COMMON relay K27

 

94 

NO relay K28

 

31 

NO relay K29 

63 

COMMON relay K28

 

95 

NO relay K30 

32 

NO relay K31 

64 

COMMON relays 
K29,K30,K31,K32 

96 

NO relay K32 

 

 

 

Содержание YAV90132

Страница 1: ...TECHNICAL DESCRIPTION YAV90132 YAV90133 32 channel 2A SPDT Relays ...

Страница 2: ...GUIDELINES 3 3 DESCRIPTION 4 4 LAYOUT AND DIMENSIONS 4 5 RELAY DISTRIBUTION 5 6 PINOUT FRONT 6 7 CONNECTOR PINOUT REAR 7 8 LED BEHAVIOUR 8 9 SWITCH CONFIGURATION 8 10 HARDWARE SPECIFICATIONS 9 11 OPERATION 10 11 1 PHI6 EXPLORER soft interface 10 12 LOW LEVEL CAN COMMANDS 11 13 ACCESSORIES 12 14 UNPACKAGING AND INSTALLING 12 ...

Страница 3: ...erating failure of the lift when such failure is due to the parameters incorrect programming The product described in this manual can be configured to comply with the ruling of different countries The manufacturer does not hold any responsibility if the company installing it does not configure it according to the legal commercial or security prescriptions that may be in force in the place of insta...

Страница 4: ...28 relays SPDT NO or NC depending on fixture wiring 1x 4 relays NO sharing the common pin P N YAV90132 contacts are for general purpose applications and up to 2A continuous current being P N YAV90133 with the same functionality and electrically compatible has contacts designed to carry a maximum of 2A but with better behaviour for low voltage signals 4 LAYOUTAND DIMENSIONS All dimensions are in mi...

Страница 5: ...Pag 5 13 www 6tlengineering com 18 06 2022 YAV90132 YAV90133 5 RELAY DISTRIBUTION ...

Страница 6: ...NC relay K12 46 COMMON relay K11 78 NO relay K12 15 NC relay K13 47 COMMON relay K12 79 NO relay K13 16 NC relay K14 48 COMMON relay K13 80 NO relay K14 17 NC relay K15 49 COMMON relay K14 81 NO relay K15 18 NC relay K16 50 COMMON relay K15 82 NO relay K16 19 NC relay K17 51 COMMON relay K16 83 NO relay K17 20 NC relay K18 52 COMMON relay K17 84 NO relay K18 21 NC relay K19 53 COMMON relay K18 85 ...

Страница 7: ...7 CONNECTOR PINOUT REAR X1 Connector Power and CAN Pin Number Signal Description 1 GND Ground connection 2 24V Board power supply 3 CAN L CAN Bus Low signal 4 CAN H CAN Bus High signal X1 pinout description Plug type Manufacturer Weidmuller Model BLZF 3 50 04 180 ...

Страница 8: ...ation speed 3 to 8 The logic address is composed by 2 elements the module identification and the hardware address The module identification is set on firmware and cannot be changed The hardware address is selected by switches 3 to 8 being 3 the least significant bit LSB and 8 the most significant bit MSB ON 1 2 3 4 5 6 7 8 ON 1 OFF 0 LSB MSB Board Address SW1 behaviour Switch ID Description Defini...

Страница 9: ...ays contact specifications Property Min Typ Max Units Maximum switching power AC 1250 VA Mechanical endurance 15x10 6 Cycles Electrical endurance 100000 Cycles Maximum electrical operation frequency 1800 Cycles h Contact resistance 50 mOhm Operate time 5 ms Release time 2 ms Bounce time 1 ms YAV90132 Relay contact specifications YAV90133 Relays contact specifications Property Min Typ Max Units Max...

Страница 10: ...p debugging of test systems or system maintenance on site Activate relays By clicking a relay in the panel the relay closes and its status in the panel is updated Reset Reset button will put all relays in Open status Config tags To operate with Phi6 driver each relay must be given a tag name By clicking this button the panel will change its background color from grey to yellow and tag name can be ...

Страница 11: ...xx 4 0x03 0x02 Relay Status Set OFF Several Relays Rx 0x155103xx 7 0x03 0x03 Relays 0 Relays 1 Relays 2 Relays 3 0x00 Set ON Several Relays Rx 0x155103xx 7 0x03 0x03 Relays 0 Relays 1 Relays 2 Relays 3 0x01 TOGGLE Several Relays Rx 0x155103xx 7 0x03 0x03 Relays 0 Relays 1 Relays 2 Relays 3 0x02 BLINK Several Relays Rx 0x155103xx 7 0x03 0x03 Relays 0 Relays 1 Relays 2 Relays 3 0x03 PULSE ON Several...

Страница 12: ...m packed to avoid the intrusion of external agents during transport and storage and on an antistatic package To start using the product just remove vacuum bag carefully to avoid damage To install the YAV90132 YAV90133 simply insert the module on a VPC receiver vertical or horizontally according to the Receiver arrangement Once it is completely inserted fix YAV module with two 4 40 UNC screws on ea...

Страница 13: ...Pag 13 13 www 6tlengineering com 18 06 2022 YAV90132 YAV90133 Finally connect the X1 rear plug of CAN bus and power supply 24VDC to start using the module ...

Отзывы: