IMPORTANT SAFEGUARDS

Incorrect installation or misuse of the power inverter may result in danger to the user or create hazardous conditions. 

We urge you to pay special attention to all CAUTION and WARNING statements. CAUTION statements identify 

conditions or practices that may result in damage to the power inverter or to other equipment. WARNING statements 

identify conditions that may result in personal injury or loss of life.

   WARNING! Shock hazard. Keep away from children.

• 

The power inverter generates the same potentially lethal AC power as a normal household wall outlet. Treat it as 

you would any other AC outlet.

• 

Do not insert foreign objects into the power inverter’s AC outlet, fan or vent openings.

• 

For indoor use only - do not expose the power inverter to water, rain, snow or spray.

• 

Do not, under any circumstance, connect the power inverter to AC Power.

   WARNING! Heated surface.

• 

The power inverter’s housing may become uncomfortably warm, reaching 60°C (140°F) under extended high 

power operation. Ensure at least 5 cm (2 inches) of air space is maintained on all sides of the power inverter. During 

operation, keep away from materials that may be affected by high temperature. 

   WARNING! Explosion hazard.

• 

Do not use the power inverter in the presence of flammable fumes or gases, such as in the bilge of a petrol 

powered boat, or near a propane tank. Do not use the power inverter in an enclosure containing automotive-type, 

lead-acid batteries. These batteries, unlike sealed batteries, vent explosive hydrogen gas which can be ignited by 

sparks from an electrical connection.

• 

When working on electrical equipment always ensure someone is nearby to help you in an emergency.

   CAUTION!

• 

Do not connect live AC power to the power inverter’s AC outlets. The power inverter will be damaged even if it is 

switched OFF.

• 

Do not expose the power inverter to temperatures exceeding 40°C (104°F).

   CAUTION! Do not use the power inverter with the following equipment:

• 

Small battery operated products such as rechargeable flashlights, some rechargeable shavers, and night lights that 

are plugged directly into an AC receptacle to recharge.

• 

Certain battery chargers for battery packs used in hand powered tools. These chargers will have warning labels 

stating that dangerous voltages are present at the charger’s battery terminals.

   CAUTION! Don’t disassemble or modify the power inverter.

IMPORTANT NOTE: This unit is a modified sine wave inverter. You should always check in your appliance 

user manual to know whether a modified sine wave power inverter is compatible. If it is NOT stated in your 

appliance manual, please contact the manufacturer to seek advise on whether this inverter is suitable for 

your appliance. Natural Product Solutions Pty Ltd will not be held responsible if the power inverter damages 

your appliance if a pure sine wave inverter should have been used.

Содержание GO OFF ROAD

Страница 1: ...ER GUIDE For Indoor Use Only 1x600WPowerInverter 1xSetPowerCableswithBattery Clamps 1xUSBPortCompatibleMultiAdapter 1xPortablePowerBank 1800Li ion Battery 1xUSBChargingLeadforPortable PowerBank 1xUserGuide 1xWarrantyCard Version 2 June 2015 ...

Страница 2: ...S 4 PORTABLE POWER BANK 4 IMPORTANT SAFEGUARDS 5 SAFETY FEATURES 6 OPERATING ENVIRONMENT 6 CONTROL FUNCTIONS 6 LED POWER INDICATOR 7 USB OUTLET 7 INSTRUCTIONS FOR USE 8 CONNECTION TO THE POWER SUPPLY 8 CONNECTING AN APPLIANCE 9 RECHARGEABLE UNITS 9 FUSE 9 MAINTENANCE CLEANING 10 DISPOSAL 10 TROUBLESHOOTING 11 SPECIFICATIONS 11 ...

Страница 3: ...arts Notice Unfortunately from time to time faulty products are manufactured which need to be returned to the Supplier for repair Please be aware that if your product is capable of retaining user generated data such as files stored on a computer hard drive telephone numbers stored on a mobile telephone songs stored on a portable media player games saved on a games console or files stored on a USB ...

Страница 4: ...he warnings key information and recommendations within this user guide This power inverter complies with AS NZS 4763 2011 INTENDED USE This product is designed to provide power to AC appliances via a 12VDC power source Private domestic use only CONTENTS 1 x 600W Power Inverter 1 x Set Power Cables with Battery Clamps 1 x USB Port Compatible Multi Adapter 1 x Portable Power Bank 1800 Li ion Battery...

Страница 5: ...t or near a propane tank Do not use the power inverter in an enclosure containing automotive type lead acid batteries These batteries unlike sealed batteries vent explosive hydrogen gas which can be ignited by sparks from an electrical connection When working on electrical equipment always ensure someone is nearby to help you in an emergency CAUTION Do not connect live AC power to the power invert...

Страница 6: ...ion to polarity when attaching the clamps to the battery Red terminal is positive and black terminal is negative 7 High speed cooling fan The fan cools the internal circuits automatically while the power inverter is in operation mode WARNING Before using the 4 x 4 tough inverter you must provide an earth connection to the inverter operating the inverter without a proper earth connection may cause ...

Страница 7: ...watts 100 500 600 watts THE SHADED BOX SHOWS AN APPROXIMATE PERCENTAGE THAT WILL BE DISPLAYED ON YOUR POWER INVERTER AND ARE A GUIDELINE ONLY Depending on the usage and the battery level from time to time the above two readings may present the same number this will only remain the same for a short period of time and will vary as battery level increase decreases or load applied to the power inverte...

Страница 8: ... the battery Red terminal is positive and black terminal is negative See Fig 1 The power inverter can be operated when the motor is running or when the motor is at a standstill It is possible that the power inverter may not work due to the voltage drop during the starting process If not in use disconnect the power inverter from the battery Alarm in case of Battery Voltage Drop The power inverter s...

Страница 9: ...n the specifications of the power inverter Insert the plug into a socket of the power inverter Press the On switch when the green LED lights up the unit is operational The LED will turn off if the voltage drops below 10 V and the power inverter switches off switch off the appliance and disconnect the plug If the external flexible cord of this inverter is damaged it shall be replaced by a special c...

Страница 10: ...ouncils hold e waste electronic waste collections Contact your nearest council to enquire about the best method of disposal in your area FAQ Q The unit has started but the appliance keeps switching off A Some inductive motors may require 2 6 start up attempts If an appliance you have attached to the inverter only runs for a moment when the power is supplied switch the power inverter on and off qui...

Страница 11: ...eads are incorrectly attached and the unit fails to operate it will be because the fuses have blown You will need to take the unit to a certified licensed electrician to have the fuses replaced Under no circumstance are unlicensed electrical persons permitted to open the unit to replace fuses or conduct other repairs Check that the wires are connected correctly when connecting the power inverter s...

Страница 12: ...12 4x4 TOUGH GO OFF ROAD is a trademark of Natural Product Solutions Pty Ltd Unit 3 60 Box Road Taren Point NSW 2229 Phone 1300 883104 www 4x4tough com au sales 4x4tough com au ...

Отзывы: