TROUBLESHOOTING

PROBLEM

CAUSE

RECOMMENDATION

Low outgoing voltage.
Note: Only use RMS voltmeters to 

measure the outgoing voltage.

The power inverter is overloaded

Reduce the outgoing output.

Incoming voltage is below 10 volt. Ensure adequate incoming voltage of over 10 

volt.

Battery power is too low.

Poor condition of the battery.

Replace the battery.

Inadequate power supply or 

inappropriate voltage drops.

Check the condition of the battery clamps.

No output.

The power inverter is not at 

operating temperature.

Switch the power inverter off and on again. 

If necessary, repeat the process until the 

attached appliance starts.

Battery voltage below 10 Volt.

Charge or exchange the battery

Power inverter has cut-off 

automatically due to overheating.

Allow the power inverter to cool down. Ensure 

there is enough air circulation.

The fuse has blown.

In the event that the leads are incorrectly 

attached and the unit fails to operate, it will 

be because the fuses have blown. You will 

need to take the unit to a certified licensed 

electrician to have the fuses replaced. Under no 

circumstance are unlicensed electrical persons 

permitted to open the unit to replace fuses 

or conduct other repairs. Check that the wires 

are connected correctly when connecting the 

power inverter (see diagram on Page 9).

SPECIFICATIONS

OUTPUT

RATED OUTPUT POWER

240VAC, 50Hz, 2.5A, 500VA (continuous), 600VA (10 minutes)

SURGE POWER

1200VA

FREQUENCY

50Hz

AC REGULATION

± 10%

AC VOLTAGE

240V AC

WAVEFORM

                  Modified sine wave

USB PORT

5V, 500mA DC

INPUT

RATED INPUT POWER

12V DC , 56A

NO LOAD-

≤ 0.5A

DC VOLTAGE

12V DC

EFFICIENCY (Typ.)

≥ 80%

FUSE

35AMP X 2

PROTECTION

BATTERY LOW ALARM

10V DC ± 0.5V

BATTERY LOW SHUTDOWN

9.5V DC ± 0.5V

OUTPUT OVERLOAD PROTECTION

≥ 720W

Shut off output voltage, re-power on to recover

OVER VOLTAGE

15.5 ± 0.5V

OVER TEMPERATURE

>65°C ± 5°C

OUTPUT SHORT

Auto. Shut-off

BATTERY POLARITY

By fuse

CLASSIFICATION

Equipollently bonded inverter

DIMENSIONS

220 x 155 x 65mm

Содержание GO OFF ROAD

Страница 1: ...ER GUIDE For Indoor Use Only 1x600WPowerInverter 1xSetPowerCableswithBattery Clamps 1xUSBPortCompatibleMultiAdapter 1xPortablePowerBank 1800Li ion Battery 1xUSBChargingLeadforPortable PowerBank 1xUserGuide 1xWarrantyCard Version 2 June 2015 ...

Страница 2: ...S 4 PORTABLE POWER BANK 4 IMPORTANT SAFEGUARDS 5 SAFETY FEATURES 6 OPERATING ENVIRONMENT 6 CONTROL FUNCTIONS 6 LED POWER INDICATOR 7 USB OUTLET 7 INSTRUCTIONS FOR USE 8 CONNECTION TO THE POWER SUPPLY 8 CONNECTING AN APPLIANCE 9 RECHARGEABLE UNITS 9 FUSE 9 MAINTENANCE CLEANING 10 DISPOSAL 10 TROUBLESHOOTING 11 SPECIFICATIONS 11 ...

Страница 3: ...arts Notice Unfortunately from time to time faulty products are manufactured which need to be returned to the Supplier for repair Please be aware that if your product is capable of retaining user generated data such as files stored on a computer hard drive telephone numbers stored on a mobile telephone songs stored on a portable media player games saved on a games console or files stored on a USB ...

Страница 4: ...he warnings key information and recommendations within this user guide This power inverter complies with AS NZS 4763 2011 INTENDED USE This product is designed to provide power to AC appliances via a 12VDC power source Private domestic use only CONTENTS 1 x 600W Power Inverter 1 x Set Power Cables with Battery Clamps 1 x USB Port Compatible Multi Adapter 1 x Portable Power Bank 1800 Li ion Battery...

Страница 5: ...t or near a propane tank Do not use the power inverter in an enclosure containing automotive type lead acid batteries These batteries unlike sealed batteries vent explosive hydrogen gas which can be ignited by sparks from an electrical connection When working on electrical equipment always ensure someone is nearby to help you in an emergency CAUTION Do not connect live AC power to the power invert...

Страница 6: ...ion to polarity when attaching the clamps to the battery Red terminal is positive and black terminal is negative 7 High speed cooling fan The fan cools the internal circuits automatically while the power inverter is in operation mode WARNING Before using the 4 x 4 tough inverter you must provide an earth connection to the inverter operating the inverter without a proper earth connection may cause ...

Страница 7: ...watts 100 500 600 watts THE SHADED BOX SHOWS AN APPROXIMATE PERCENTAGE THAT WILL BE DISPLAYED ON YOUR POWER INVERTER AND ARE A GUIDELINE ONLY Depending on the usage and the battery level from time to time the above two readings may present the same number this will only remain the same for a short period of time and will vary as battery level increase decreases or load applied to the power inverte...

Страница 8: ... the battery Red terminal is positive and black terminal is negative See Fig 1 The power inverter can be operated when the motor is running or when the motor is at a standstill It is possible that the power inverter may not work due to the voltage drop during the starting process If not in use disconnect the power inverter from the battery Alarm in case of Battery Voltage Drop The power inverter s...

Страница 9: ...n the specifications of the power inverter Insert the plug into a socket of the power inverter Press the On switch when the green LED lights up the unit is operational The LED will turn off if the voltage drops below 10 V and the power inverter switches off switch off the appliance and disconnect the plug If the external flexible cord of this inverter is damaged it shall be replaced by a special c...

Страница 10: ...ouncils hold e waste electronic waste collections Contact your nearest council to enquire about the best method of disposal in your area FAQ Q The unit has started but the appliance keeps switching off A Some inductive motors may require 2 6 start up attempts If an appliance you have attached to the inverter only runs for a moment when the power is supplied switch the power inverter on and off qui...

Страница 11: ...eads are incorrectly attached and the unit fails to operate it will be because the fuses have blown You will need to take the unit to a certified licensed electrician to have the fuses replaced Under no circumstance are unlicensed electrical persons permitted to open the unit to replace fuses or conduct other repairs Check that the wires are connected correctly when connecting the power inverter s...

Страница 12: ...12 4x4 TOUGH GO OFF ROAD is a trademark of Natural Product Solutions Pty Ltd Unit 3 60 Box Road Taren Point NSW 2229 Phone 1300 883104 www 4x4tough com au sales 4x4tough com au ...

Отзывы: