6 core cable

Speed control pot

Battery Condition Meter

Ignition wire removed

To fit battery discharge

protection.

Reverse switch

Ignition switch

Black

Green

Blue

Red

Black

Black

Blue

Red

Red

Red

Yellow

White

R     fitted (12K)

uvp

Permanent
magnet
motor

Yellow

White
Black

Green

Blue

Red

Fuse or breaker, see text

 The diagram shows the simplest  connections needed
to use the controller. 

 More information on wiring follows.

Yellow is directly connected to bve. White
and black may also be bve (depending on the
control switches). Green is battery -ve and blue and
red are the control pot.

Fuse in yellow wire is optional but recommended -
see p 15.

7

Connections

8.01

Battery wiring

Use only good quality battery connectors: the
controller feeds current back the battery during
braking and if a battery connector falls off when
braking this regenerated current can pump up the
voltage on the dud battery connection. Although the
controller is protected against damage, this is not
advised since control is lost. The same will happen if
a fuse or circuit breaker opens during braking.

Wire size.

Use heavy duty wire for the battery leads and make
them as short as possible. This also applies to the
battery linking wire on 24v systems. 

4mm (12awg) wire is ‘officially’ rated to handle 41
amps continuously. At 100 amps it gets too hot to
touch within about 60 seconds. We therefore suggest
you use at least 6.0mm² (10awg) wire for battery
connections. 

On the 12v controllers, voltage loss in the wire is
important and you may need to use two lengths of
6mm² wire for the battery - depending on their
length. Excessive voltage loss will cause the voltage

8

Power Connections

Содержание Pro-120 Series

Страница 1: ...vailable either for 24v operation or for 12v operation Models can also be supplied for 36v and 48v The voltage is marked on the relays Make sure this are correct as 24v relays will not operate from 12...

Страница 2: ...and electromagnetic brake driver Many of these features can be disabled if so required The simplest configuration is shown in section 7 However because of the features and versatility of our controll...

Страница 3: ...raking may have difficulty in operating as it has to overcharge the battery A similar problem exists if the battery is disconnected or the wiring faulty There are several options as to how the control...

Страница 4: ...Reverse Gain Accel MST RAT Decel Expansion connector HPLO Thermal sensor Trickle resistor UVP Brake drive transistor Battery Controls Parking brake Motor Motor Battery A B C D F E A B C RB1 RB2 Revers...

Страница 5: ...er won t cause damage unless the unit is connected to the battery when electrolytic corrosion will occur See also section 15 Supply voltage 12v or 24v or 36v or 48v different models Supply current 30m...

Страница 6: ...tery connectors the controller feeds current back the battery during braking and if a battery connector falls off when braking this regenerated current can pump up the voltage on the dud battery conne...

Страница 7: ...ckly disconnect the motor in an emergency Also with the motor disconnected freewheeling becomes possible It is also possible to get a battery isolator switch these are normally fitted to lorries buses...

Страница 8: ...nternal capacitor charging through a bleed resistor before the ignition switch is closed Beware of opening the switch when the motor is running the motor will brake to a halt more or less quickly depe...

Страница 9: ...onnections diagram page 7 For variable cutback you could fit a variable resistor Or you could use a switch to enable disable the feature The level at which it works is controlled by the value of the e...

Страница 10: ...deceleration rates These are user adjustable and to get best performance from your machine you should adjust them Acceleration ramp This is shown as Accel on the Features diagram It is present to make...

Страница 11: ...ink disconnected they will be independent The two motors will perform identically but with independent current limits If two motors are used off one single 200 amp controller then the full 200 amps cu...

Страница 12: ...extra holes in the base swarf could get into the controller and this will invalidate any warranty 13 Heat Heatsinking The long time current the controller can give is limited by the build up of heat i...

Страница 13: ...Page 13 Pro 120 controller instructions 113 9 181 166 121 118 0 0 3 15 47 8 73 2 A A B B B B 50 60 5 C 126 C...

Страница 14: ...ssion capacitor a ceramic type of 10n value is ideal If the motor does not include this you are advised to fit one across the brushes as close as possible to the motor body The controller will work wi...

Страница 15: ...amage to the controller is there is an external wiring fault There are three special sections of track which should blow if a major fault occurs in the controls or the brake connected to the 6 pin and...

Страница 16: ...the drive MOSFETs cause their drive resistors to burn up a sure sign the MOSFET has failed Relay drop out A flat battery or wiring which is too thin can cause excessive voltage drop If the supply volt...

Отзывы: