5.6 Error Messages
If a fault condition occurs, an error message will be displayed and the LED will flash red. The error will be
logged in the Fault Log. Normal operation will continue once the immerSUN is reset.
Error Messages
●○
UNIT TEMPERATURE
TOO HOT
The internal temperature of the immerSUN is too high.
Check vents are clear.
MAINS VOLTAGE
TOO HIGH
MAINS VOLTAGE
TOO LOW
AC supply voltage is outside of the operating
parameters.
ERROR
CLAMP REVERSED
The clamp has been reversed,
the settings will need to be reset to reconfigure the unit.
(See section 4.3
Reset Settings
)
ERROR
OUTPUT OVERLOAD
The output of the unit is overloaded, the heater is larger
than 3kW.
ERROR
TRIAC FAILED
The power control has a fault, switch off the immersion
heater immediately as power may be being drawn from
the grid.
Setup Errors
ERROR! HEATER
NOT DETECTED
No load was detected during setup, the immersion
heater may be switched off at the isolator, or the
thermostat open because the water is hot already.
Otherwise there may be a fault with the immersion
heater.
CLAMP CURRENT
TOO LOW!
If the import power is too small during setup, this
message will be displayed. This could be because the
inverter is still switched on (after request to be switched
off), the heater thermostat is open, or the clamp is at the
wrong location. The clamp needs to 'see' the exported
power to the grid.