RELAY FUNCTION
>Threshold<
Threshold (Threshld)
Relay operates when an export threshold is reached,
relay remains activated for set period of time, even if
export drops. Export threshold level and relay on
duration can be set as shown below:
THRESHOLD SET
Export: 500W
THRESHOLD SET
Duration: 1h30m
RELAY FUNCTION
>Fault Signal<
Fault Signal (Fault)
Relay is deactivated if a fault condition occurs.
RELAY FUNCTION
>Always On<
Always On (ON)
Relay is operated continuously.
(This is for testing purposes only).
RELAY FUNCTION
>Always Off<
Always Off (OFF)
Relay is disabled. (This is the default relay function).
Nominal Voltage
INSTALLER MENU
Nom Voltage 240V
NOMINAL VOLTAGE
>240< Volts
Nominal Voltage
The nominal mains operation voltage should be set.
Default is 240V.
Reset Settings
INSTALLER MENU
Reset Settings
RESET SETTINGS
CONFIRM Press >
Reset Settings
Use to setup immerSUN after installation.
(See section 4.2).
Serial Number &
Firmware
Version
INSTALLER MENU
S/N:123456 V1.10
Serial Number & Firmware Version
The serial number and firmware version are displayed.
17