background image

 

5 of 31 

 

CUSTOMER SAFETY RESPONSIBILITIES 

4B appreciates your business and is pleased you have chosen our products to meet 

your needs. 
Please read in its entirety and understand the literature accompanying the product 

before you place the product into service.  Please read the safety precautions carefully 

before operating the product.  With each product you purchase from 4B, there are 

some basic but important safety considerations you must follow to be sure your 

purchase is permitted to perform its design function and operate properly and safely, 

giving you many years of reliable service.  Please read and understand the Customer 

Safety Responsibilities listed below.  Failure to follow this safety directive and the 

Operation Manuals and other material furnished or referenced, may result in serious 

injury or death. 

SAFETY NOTICE TO OUR CUSTOMERS 

A.

 

In  order  to  maximize  efficiency  and  safety,  selecting  the 

right equipment for 

each operation is vital.  The proper installation of the equipment, and regular 

maintenance and inspection is equally important in continuing the proper 

operation and safety of the product.  The proper installation and maintenance 

of all our products is the responsibility of the user unless you have asked 4B to 

perform these tasks. 

B.

 

All installation and wiring must be in accordance with Local and National 

Electrical Codes and other standards applicable to your industry.  (Please see 

the  article  “Hazard  Monitoring  Equipment  Selection,  Installation  and 

Maintenance” a

www.go4b.com/usa

).  The installation of the wiring should be 

undertaken by an experienced and qualified professional electrician.  Failure to 

correctly wire any product and/or machinery can result in the product or 

machine failing to operate as intended, and can defeat its design function. 

C.

 

Periodic inspection by a qualified person will help assure your 4B product is 

performing properly.  4B recommends a documented inspection at least 

annually and more frequently under high use conditions. 

D.

 

Please see the last page of this manual for all warranty information regarding 

this product. 
 

CUSTOMER SAFETY RESPONSIBILITIES 

1.

 

READ ALL LITERATURE PROVIDED WITH YOUR PRODUCT 

Please read all user, instruction and safety manuals to ensure that you understand 

your product operation and are able to safely and effectively use this product.  If the 

Содержание USR1V4

Страница 1: ...INSTRUCTION MANUAL REV121723 Approvals Speed Relay Digital Speed Monitor Part Number USR1V4 USR1V46...

Страница 2: ...siguiente c digo QR PT Para baixar a vers o digital deste manual de instru es e veri car outros idiomas dispon veis escaneie o seguinte c digo QR FR Pour t l charger la version num rique de ce manuel...

Страница 3: ......

Страница 4: ...USTOMER SAFETY RESPONSIBILITIES 5 PRODUCT OVERVIEW 8 PACKAGE CONTENT 8 SPECIFICATIONS 9 APPROVALS 10 DIMENSIONS 10 CONDITIONS OF USE 11 STANDARD WIRING DIAGRAM 11 INSTALLATION 15 GRAPHICAL USER INTERF...

Страница 5: ...ing the proper operation and safety of the product The proper installation and maintenance of all our products is the responsibility of the user unless you have asked 4B to perform these tasks B All i...

Страница 6: ...other product installation information supplied with the product You should be prepared to provide the installer with all necessary installation information to assist in the installation 4 ESTABLISH A...

Страница 7: ...EST If you have questions or comments about the operation of your unit or require the unit to be serviced please call the 24 hour hotline number 309 698 5611 contact your local distributor or use one...

Страница 8: ...ncy in a range of selectable units The user can set the Electromechanical Relay and PhotoMOS Solid State Relay outputs independently with their own thresholds and output behaviors and have the Alarm L...

Страница 9: ...s 30 VDC 250 VAC 2 5 A MAX SSR Output Contacts 230 V AC DC 100 mA Interlock Input 18 to 28 VDC 85 to 264 VAC Indication 1x Red Alarm LED 1x Green Input LED 1x 160x80 LCD display Sensor Input Frequency...

Страница 10: ...10 of 31 APPROVALS In Process DIMENSIONS ALL DIMENSIONS IN MM...

Страница 11: ...es e g NEC CEC EN IEC 60079 14 and should be undertaken by an experienced and quali ed electrician All wiring must be in accordance with local and national electrical codes and should be undertaken by...

Страница 12: ...P Sensor Input Input 18 to 28 VDC 4 NPN Sensor Input Output 24 VDC 50 mA 5 SSR Output A Input 230 V AC DC 100 mA 6 SSR Output B 7 Earth USR1V46 Only Input 85 to 264 VAC 50 to 60 Hz 0 03A at 230 VAC 8...

Страница 13: ...ensor Wiring 2 Wire PNP Sensor Wiring 3 Wire sensors such as types E NPN E2 PNP and E3 NPN PNP Rotech Encoders 3 Wire NPN Sensor Wiring 3 Wire PNP Sensor Wiring 4 Wire sensors such as P1003V34AI P3003...

Страница 14: ...supply from pin 1 to power a sensor which is rated for 100 mA A 2 wire NPN sensor can be powered from Terminal 4 which is rated for 24 VDC 50 mA If the Speed Relay is powered via DC using terminals 1...

Страница 15: ...o NOT USED the state of the interlock does not matter INSTALLATION The Speed Relay should be wired as show in the connection diagrams in Electrical Setup Speed Relay Mounted on 35mm DIN rail The Speed...

Страница 16: ...th Screwdriver GRAPHICAL USER INTERFACE Splash Screen Splash Screen Description Initial screen displayed for 4 seconds on start up before transitioning to the runtime screen Contents Device Name 4B Lo...

Страница 17: ...n RUN is displayed in place of start up icon when the system has the Interlock connected and the start up delay has elapsed or if the interlock is not being used Contents Alarm Icon ALM Run Icon RUN S...

Страница 18: ...Save Profile Screen 11 Load Profile Transitions to the Load Profile Screen 12 Test Outputs Transitions to the Test Screen 13 Manual QR code Transitions to the QR code screen 14 Factory Reset Transiti...

Страница 19: ...selected digit indicator calibration point value PPM Controls Up button increases the selected digit by 1 to a maximum PPM of 60000 Down button decreases the selected digit by 1 to a minimum PPM of 0...

Страница 20: ...SSR Output Range The SSR Output triggers outside the selected range Relay Follow SSR Output uses the settings for the relay output Pulse SSR Output pulses at the measured input frequency Alarm LED Re...

Страница 21: ...increases the selected digit by 1 to a maximum PPM of 60000 or unit equivalent Down button decreases the selected digit by 1 to a minimum PPM of 0 or unit equivalent Enter button selects the next digi...

Страница 22: ...u Factory Reset Screen System Reset Screen Description The factory reset screen allows the user to wipe all user settings from the Speed Relay All saved settings will return to the default values Cont...

Страница 23: ...creen this will load the selected pro le and return to the system menu And on the save screen this will save the current settings into the selected pro le slot and transition to the system menu Test S...

Страница 24: ...24 of 31 Manual Screen Manual Screen Description The Manual screen displays a QR code that links to the URL of the product manual Contents QR code Controls Enter button Transition to the System menu...

Страница 25: ...y How long the unit waits after starting up or turning on the Interlock before measuring the input against the thresholds 0 0 100 0 s 5 0 s Screen Sleep Delay The length of the period of inactivity re...

Страница 26: ...setpoint for the SSR Output 0 60000 PPM or unit equivalent 0 PPM SSR Output Setpoint Max The second setpoint for the SSR Output 0 60000 PPM or unit equivalent 0 PPM Alarm LED Option The output of the...

Страница 27: ...o the correct input terminal of the unit e g NPN sensor wired to the NPN input terminal 4 Make sure sensor is outputting pulses correctly 0 PPM is displayed even though Input LED is ashing 1 Make sure...

Страница 28: ...ical connections are secure and in good order 3 Test that the Speed Relay receives input pulses with the Input LED ashing and a speed calculated on the display 4 Test that the outputs trigger using th...

Страница 29: ...29 of 31 NOTES...

Страница 30: ...t are due to product misuse abuse or misapplications as authorized by law 4B speci cally disclaims all warranties that the product is t or merchantable for a particular purpose 3 NO WARRANTY BY SAMPLE...

Страница 31: ...iland 4B Asia Paci c Build No 899 1 Moo 20 Soi Chongsiri Bangplee Tam Ru Road Tanbon Bangpleeyai Amphur Bangplee Samutprakarn 10540 Tel 66 0 2 173 4339 France 4B France 35 bis rue du 8 mai 1945 Viller...

Отзывы: