Installation
4
Warning:
The wiring MUST be carried out by a qualified technician.
Warning:
Connect the device to a line adequately protected against short circuits and heat overloads in excess of
the applicable maximum rated power.
Warning:
Connect the device as set out by local regulations.
Warning:
Do not perform any wiring while the device is powered up.
4.1 General instructions
4.2 Positioning
When choosing where to install Power Reducer, you must consider the following factors:
a) location of the power cable of the immersion
b) recirculating air
c) (E4U ONLY) distance between Power Reducer and Elios4you
The length of the 0-10V connection cables between Power Reducer and Elios4you must not exceed 10 meters.
0-10 V max 10m
230 V ~
230 V ~
Power Reducer shares the same power source as the resistive load. Install the Power Reducer along the path
followed by the cable of the immersion.
Power Reducer must be positioned in an area with adequate ventialtion, in order to have a an efficient cooling
system. As far as possible, choose open areas with windows, avoiding closets or narrow spaces.
Pag 5
230 V ~
230 V ~
Stand Alone version
Elios4you version
SA
E4U