4-noks srl
Via per Sacile, 158 31018 Francenigo di Gaiarine (TV) ITALY
Tel +39 0434 768462 Fax +39 0438 694617
www.4-noks.com [email protected]
Main features
Suply Voltage:
230V ±15%
Supply Frequency:
50 Hz
Load Size:
3 kW - Max 3,2 kW
Load Current:
13 A - Max 16 A
Analog Input (0-10Vdc):
0-10Vdc directly supplied by Power Reducer - max current 40 mA
Reading accuracy: ±1%
Input impedence:~5 KOhm
Power:
PWM a 19,2 KHz
Working Temperature:
from -5°C to 40°C
Protection rate:
IP 20
Weight:
3,9 Kg
Dimensions:
3
Pag 4
24 19
70,5
277
294
309
15
System Requirements
The electrical load (immersion) connected to a Power Reducer has to be a pure resistive load that does not exceed the
related power of Power Reducer itself (3kW).
(E4U ONLY)
The firmware version installed on the Elios4you
TOP
must be
V1054 build 72
or higher. The
system can not work properly with older firmware versions. Check the version from the App in the “Update” menu. If
necessary, update the App by clicking “Update App via 4-Cloud”. It is then suggested to select “Install Firmware” to
update the device with the latest firmware version from App.
(E4U ONLY) It is necessary that the installation of Elios4you is completed correctly before proceeding with
the installation of Power Reducer. Verify the orientation of CTs (Current Transformer) and the correct wiring of Elios4you.
Make sure that the App shows the proper values of the system energy flows, making sure that the Elios4you LEDs diagno
-
sis confirms the flows of energy represented by the graphics. For further information, check the Elios4you documentation.
2
E4U
E4U