Hardware and Installation Manual
|
VISIX V-Series All-in-One Cameras
–
Gen I
12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC
74
DI Sensor:
It is used for connecting a device such as a PIR and a door/window sensor.
Refer to the table below for electrical wiring information:
DO
Function
Specifications
C
Ground
1
Input
0 to 5 VDC
Max load: 50mA
Then, the connected device can be activated via its webpage.
6.5.2
CAMERA CONNECTOR
2).
Connect the camera unit to the main unit by inserting the camera
’
s DIN connector to the camera
’
s
connector on the main unit by placing the arrow mark to be shown upward like the image below.
NOTE:
Please make sure that the camera unit needs to be connected to the main unit prior to the
power connection. Otherwise, the camera may fail to show image.
+3.3V
DI
COM
DI
COM
+
-
Relay Type
Voltage Type
+
-
Output of
Sensor
Output of
Sensor
Internal
Internal
+
-
C
1
C
1
D
O
DI
D
❶
❸
❹
❷
❷