 Do not expose the tubular motor to crushing, impact, falling or contact with any liquids. 

  Do not punch holes in the entire length of the tube (motor casing) or attach screws to it.

 Please use suitable suspension springs to fasten the roller shutter curtain to the roller shutter shaft.

  You will find suitable suspension springs on page 19 and in our store under mounting accessories.

 Important for motor type 3T35-R (SW40):

  It is essential to use mini suspension springs for motor operation. These special mini springs protrude only approx. 
  1 mm into the shaft. This allows the shaft to rotate freely. When using commercially available suspension springs  
  the motor housing is left with grinding marks because the suspension pin protrudes too far into the roller shutter shaft,  
  which leads to damage and destruction of the motor.

 

For steel shafts with a width across flats of 40 mm (SW40), only use shafts with 

  an external fold. Steel shafts with an internal fold will damage and destroy the motor. 

 Grinding marks of any kind on the motor housing will void the warranty.

 The inspection cover of the roller shutter box must be easily accessible and removable.

 We recommend using a tubular motor with a power 10% higher than the weight of the shutter,  

  to compensate for the frictional resistance of the rail guide.

  >

 See Guideline / Determine torque (page 3)

 The motor is designed for short-time operation (4 min). It has an internal thermal circuit breaker which interrupts 

  the power supply in the event of overheating, e.g. as a result of continuous operation. The cooling phase is min. 10 min, 
  the thermal switch resets automatically. Regular operation is only possible after the the motor has cooled down completely.

Mini suspension springs (Page 19)

8-sided shaft SW40 
with external fold

  

Do not use 
8-sided shaft SW40 
with internal fold!

  

Before installation, all non-essential electrical wiring must be removed, all mechanisms 
that are not necessary for motorized operation must be deactivated.

 INSTALLATION NOTES

3T-MOTORS Radio tubular motors

  |  Installation notes

Содержание 3T-MOTORS 3T35-10R

Страница 1: ...trol via smart phone tablet PC or via voice commands with Alexa or Google Assistant INTELLIGENT DRIVES CONTROLS FOR SHUTTERS AND AWNINGS INSTALLATION OPERATING INSTRUCTIONS Instructions and notes for...

Страница 2: ...age 13 3 Mounting radio awning motor Page 13 14 4 Radio awning motor wiring Page 14 5 Programming radio transmitter Page 14 6 Setting the end positions Page 15 Programming radio transmitter Pairing ha...

Страница 3: ...ount rail guidance of approx 10 Roller shutter area m x Weight roller shutter material m Weight roller shutter kg 10 Friction losses Required traction force kg Example PVC Roller shutter area 3 00 m x...

Страница 4: ...d original accessories from the manufacturer The mains connection cable of the drives must be laid internally in the empty conduit up to the junction box The local electrical regulations must be obser...

Страница 5: ...0R 10 Nm 25 kg 4 5 m 3 m 112 W 2 W 15 U min 22 230 V 615 mm 595 mm 3 m 4 min IP44 4260336110613 3T45 20R 20 Nm 40 kg 6 m 4 7 m 145 W 2 W 15 U min 22 230 V 615 mm 595 mm 3 m 4 min IP44 4260336110101 3T...

Страница 6: ...Steel shafts with an internal fold will damage and destroy the motor Grinding marks of any kind on the motor housing will void the warranty The inspection cover of the roller shutter box must be easil...

Страница 7: ...sal bearing 3T45 R 3T35 R and covercap bearing 3T45 R clip bearing 3T35 R Use one of the two motor bearings depending on the installation situation 1 2 3 4 5 6 7 8 9 10 11 Please note The motor can be...

Страница 8: ...ips Motor type 3T35 R Installation with universal bearing or clip bearing Installation with universal bearing Push the motor with the square into the opening of the bearing and secure with cotter pin...

Страница 9: ...mit switch adapter fig 4 7 4 8 5 Mount bearings Remove old wall bearing on motor side left or right installation possible Mount motor bearing at this point 2 mounting options Universal bearing and cov...

Страница 10: ...dio transmitter Pair radio transmitter to shutter motor See Programming radio transmitter Pairing handheld transmitter to 3T radio motor type R page 16 If the direction of rotation is reversed please...

Страница 11: ...l suspension springs from the roller shutter shaft Move the motor shaft in the downward direction until the lower limit switch off occurs automatically and the motor stops Move motor shaft upwards Whi...

Страница 12: ...ternal fold the motor housing will be left with grinding marks since the suspension pin or the fold protrude too far into the roller shutter shaft Contrary to its intended use the motor runs permanent...

Страница 13: ...e support tube fig 3 4 Remove the crank mechanism fig 3 5 Attention Awning arms are under strong tension 2 1 2 2 2 3 2 4 3 1 3 2 3 2 3 4 Remove the shaft capsule from the shaft fig 3 6 If the shaft ca...

Страница 14: ...be changed via the radio transmitter p 16 3 9 3 10 3 11 3 12 Radio awning motor 230 V 50 Hz Power grid 230 V 50 Hz 1 brown black L1 Phase 2 blue N Neutral conductor 3 green yellow PE Protective conduc...

Страница 15: ...he motor is to continue moving turn the adjustment pin on the RETURN limit switch screw in the PLUS direction until the desired position is reached and the awning is fully retracted If the awning moto...

Страница 16: ...the affected receiver to voltage Pairing another handheld transmitter The motor confirms the programming with several beeps OK 1 x Press button P2 Set Up of the new handheld transmitter Beep while pre...

Страница 17: ...e and vice versa Shutter operating mode Motor immediately goes into self hold when a direction button is pressed Blind operating mode Jog mode possible Only when the direction key is pressed for longe...

Страница 18: ...limit switch screws 15 20 turns in the MINUS direction and set again first DOWN then UP the motor stops running after continuous operation The thermal protection switch of the motor has tripped After...

Страница 19: ...e 2006 42 EG EMV Richtlinie 2014 30 EU RED Richtlinie 2014 53 EU RoHS Richtlinie 2011 65 EU Delegierte Richtlinie EU 2015 863 WEEE Richtlinie 2012 19 EU angewandte Standards und Verordnungen EN 55014...

Страница 20: ...www instagram com 3tcomponents twitter com 3TComponents INTELLIGENT DRIVES CONTROLS FOR SHUTTERS AND AWNINGS Service and Quality make the difference 3T Components GmbH Co KG Bahnhofstr 34 55578 Walle...

Отзывы: