The main element configuration description of port mirror interface:
Interface Element
Description
Port Mirror
Setting port mirror function, options are:
Enable;
Disable;
Mirror port
Choose the ingress and egress data port that needs
mirroring.
Collect port
Configure the collect ports with ingress/egress data mirroring.
Collect data
Backup data during mirroring, options are:
All;
Egress.
For instance: port mirror configuration
For example: use port 4 to collect ingress data and egress data of port 1, port 2 and
port 3.
Operating steps
Step 1
Log in Web configuration page.
Step 2
Choose “Main Menu > Diagnosis > Mirror”.
Step 3
On the “Mirror” page, choose “enable” in the “mirror”.
Step 4
In the option of “mirror port”, choose port “1”, “2” and “3”.
Step 5
In the option of “collect port”, choose port “4”.
Step 6
In the option of “watch direction”, choose “all”.
Step 7
Click “Apply”.
Step 8
End.