Operation Step 1: creating ring
Configuring Device 100, 101, 102 and 103 in the following steps respectively.
Step 1
Choose “Main Menu > Redundancy > Rapid Ring”.
Step 2
In the “Settings” area of “Rapid Ring” page, choose “SW-Ring V3” as “Protocol of
Redundancy”.
Step 3
Check the “Enable” box in the “Group 1”.
Step 4
In the “settings” area of “Rapid Ring”:
1. Set “Type” to “Single”;
2. Set “ID” to “1”;
3. Set “Port 1” to “2”;
4. Set “Port 2” to “3”;
Step 5
For Device 101/102/103/104, choose “Slave” in the drop-down list of “Master-slave” of
“Group 1”.
Step 6
For Device 100, choose “Master” in the drop-down list of “Master-slave” of “Group 1”.
Step 7
Click “Apply”.