MDI (straight-through cable) 

 
 
 
 
 

 
MDI-X (Cross over cable) 

 
 
 
 
 

 

MDI/MDI-X auto connection makes switch easy to use for 

customers without considering the type of network cable. 

Serial port connection 

RS-232 adopts RJ45 connector. The PIN define is as follows:   
RS-232 port:   
 
 
 

PIN  PIN define 

Description 

TXD 

 

Transmit data 

RXD 

Received Data 

 

RTS 

Request to send 

CTS 

Clear to send 

DSR 

Data set ready 

GND 

Signal ground 

DTR 

Data terminal ready 

DCD 

Data carrier detect 

 
RS-485/422 port: 

 

Serial port  PIN  RS-485 PIN define  RS-422 PIN define 

COM2 

-- 

 

R- 

-- 

R+ 

 

GND 

GND 

D- 

T- 

D+ 

T+ 

COM1 

-- 

R- 

-- 

R+ 

GND 

GND 

D- 

T- 

10 

D+ 

T+ 

LED Indicator

 

The LED indicator on the front panel of Modbus gateway series 
can indicate the running system and the operation status, which 
makes it easy to find and solve problems, the specific meaning of 
indicator are shown in the table. 

System statue LED 

LED 

Indicate 

Description 

PWR 

ON 

Power is connected/Function natural

 

OFF 

Power is disconnected or function 
nu-natural

 

LINK 

ON 

Ethernet port connect successfully 

Flashing  Ethernet port has data transmission 

OFF 

Ethernet port connect unsuccessfully 

RX1~2 

OFF 

None data receive 

Flashing  In receiving data 

TX1~2 

OFF 

None data transmit 

Flashing  In transmitting data 

Installation

 

Before installation, confirm that the work environment meet the 
installation require, including the power needs and abundant 
space. Whether it is close to the connection equipment and other 
equipments are prepared or not.   
1. Avoid in the sunshine, keep away from the heat fountainhead or 

the area where in intense EMI. 

2. Examine the cables and plugs that installation requirements. 
3. Examine whether the cables be seemly or not (less than 100m) 

according to reasonable scheme.   

4. Screws, nuts, tools need to be prepared in advance of your own. 
5. Power: 9~48VDC power input 
6. Environment

working temperature -40

75

 

Storage Temperature: -40

85

 

Relative humidity 5%

95% 

 

Wiring Requirements 

Cable laying need to meet the following requirements:

 

1. It is needed to check whether the type, quantity and 
specification of cable match  the requirement before cable 

laying;

 

2. It is needed to check the cable is damaged or not, factory 

records and quality assurance booklet before cable laying;

 