Wiring

Wiring

Wiring

Wiring Requirements

Requirements

Requirements

Requirements

Be sure to disconnect the power cord before installing and/or wiring

your Ethernet Switch.

Calculate the maximum possible current in each power wire and

common wire. Observe all electrical codes dictating the maximum

current allowable for each wire size. If the current goes above the

maximum ratings, the wiring could overheat may causing serious

damage to your equipment. You should also pay attention to the

following items:

1. Use separate path to route wiring for power and devices. If power

wiring and device wiring paths must cross, make sure the wires

are perpendicular at the intersection point.

2. NOTE: Do not run signal or communications wiring and power

wiring in the same wire conduit. To avoid interference, wires

with different signal characteristics should be routed separately.

3. You can use the type of signal transmitted through a wire to

determine which wires should be kept separate. The rule of

thumb is that wiring that shares similar electrical characteristics

can be bundled together.

4. Keep input and output wiring separated. It is strongly advised

that you label wiring to all devices in the system when necessary.

Содержание IES205

Страница 1: ...cators make the plug and play IES205 switches easy to use and reliable These switches have been designed for harsh industrial environments IES205 series support 5 ports10 100Base T X Full Half duplex mode and auto MDI MDI X connection Packing Packing Packing Packing L L L List ist ist ist The IES205 switch is shipped with following items 1 Ethernet switch IES205 plus terminal block 1 2 Hardware In...

Страница 2: ...anel anel anel anel Layout Layout Layout Layout IES205 series industry Ethernet switches provide 5 TP ports Power Power Power Power input bottom input bottom input bottom input bottom F F F Front ront ront ront panel panel panel panel T T T Top op op op panel panel panel panel Units Units Units Units mm mm mm mm ...

Страница 3: ... used 100Ωof UTP 3 4 5 RJ 45 port support automatic MDI MDI X operation can connect the PC Server Converter and HUB Pin 1 2 3 6 Corresponding connection in MDI 1 3 2 6 3 1 6 2 are used as cross wiring in the MDI X port of Converter and HUB 10Base T 100Base TX are used in MDI MDI X the define of Pin in the table as below NO NO NO NO MDI MDI MDI MDI signal signal signal signal MDI X MDI X MDI X MDI ...

Страница 4: ...ndication LED LED State Description POWER ON Power is being supplied to power input POWER1 input OFF Power is not being supplied to power input POWER1 input OFF abnormality RJ45 Port have two LED indictor light yellow light is a port rate indictor light green light is a port link indictor light 10 100M yellow On 100M work mode 100Base TX Off 10Mwork mode 10Base T Link ACT green On TP port is activ...

Страница 5: ...as below below below below 1 Avoid in the sunshine keep away from the heat fountainhead or the area where in intense EMI 2 Examine the cables and plugs that installation requirements 3 Examine whether the cables be seemly or not less than 100m according to reasonable scheme 4 Screw nut tool provide by yourself 5 Power need 24VDC 12VDC 36VDC power input 6 Environment 40 to 75 C Storage Temperature ...

Страница 6: ...d also pay attention to the following items 1 Use separate path to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point 2 NOTE Do not run signal or communications wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separate...

Страница 7: ...oltage 12VDC 36VDC Overload Current Protection Connection 3 bit terminal block Mechanical Mechanical Mechanical Mechanical Dimensions L W H 103mm 78mm 32mm Packaging IP 30 Protection Metal case Installation DIN Rail Wall Mounting Environmental Environmental Environmental Environmental Operating Temperature 40 to 75 C Storage Temperature 45 to 85 C Ambient Relative Humidity 10 to 95 non condensing ...

Страница 8: ...gy Co Ltd Certifications Certifications Certifications Certifications Shenzhen Shenzhen Shenzhen Shenzhen 3onedata 3onedata 3onedata 3onedata Technology Technology Technology Technology Co Ltd Co Ltd Co Ltd Co Ltd Tel 86 755 26702688 Fax 86 755 26703485 www 3onedata com ...

Страница 9: ...Your Serial and Data Communications Expert Shenzhen 3onedata Technology Co Ltd ...

Отзывы: