3MillID S-Gang Keypad Reader Скачать руководство пользователя страница 8

3millID   9249 S. Broadway   Building #200   Suite 826   Highlands Ranch   CO 80129

+1 303 475 4972

[email protected]

© 3millID

100-02640-A

www.3millid.com

MANUAL

3M

S-Gang

Keypad

8

*05n#

example

*050#
*051#
*052#
*053#
*054#

.....
.....
.....
.....
.....

*06nnnnn#

example

*07n#

example

*070#
*071#
*072#
*073#
*074#
*075#
*076#
*077#

.....
.....
.....
.....
.....
.....
.....
.....

RX00 LED

PIN CODES

*05

set LED COLOUR CONFIGURATION

SITE CODE

PIN CODES

*06

set SITE CODE EMBEDDING

RX00 COLOUR

PIN CODES

*07

set LED QUIESCENT COLOUR

To set 

RX Demo 

enter:  

*051#

    once the reader has been 

placed into programming mode.

The LED may be configured to the following modes:

6

8

0

9

#

4

7

*

5

1

2

3

The following instructions give a step-by-step procedure for accessing the many features 
supported by this reader.

4.

keypad programming guide

RX standard LED configuration

RX Demo

RX buzzer

RX AWE (excluded from documentation)

RX MPS (excluded from documentation)

This option allows the SITE CODE number to be combined 
with  the  card  number  read  from  the  card  and  sent  as  the 
complete  card  info’  message.  The  unit  accepts  site  codes 
from 

0

  to 

65535

  - 

however  the  maximum  valid  value 

depends on the output format.

To  embed 

SITE  CODE  ‘123’ 

enter:  

*0600123#

    once  the 

reader has been placed into programming mode.

6

8

0

9

#

4

7

*

5

1

2

3

The  LED  may  be  configured  to  the  following  standard 
colours.

To  set  the  LED  to 

TURQUOISE 

enter:  

*076#

    once  the 

reader has been placed into programming mode.

6

8

0

9

#

4

7

*

5

1

2

3

Blue

Magenta

Yellow

Orange

Red

White

Turquoise

OFF (LED disabled when in idle mode)

Содержание S-Gang Keypad Reader

Страница 1: ...the reader may be fixed directly onto a US electrical backbox This powerfully secure and innovative reader has a beautifully clean aesthetic and a bright RGB LED that can be applied to many applicatio...

Страница 2: ...5 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference...

Страница 3: ...tage Rest 4Vdc Active 1Vdc Data Output Wiegand Clock Data Custom Outputs Indication 1 RGB LED RGB illuminated keypad Sounder Integral speaker dimensions 120mm x 76mm x 21mm 4 7 x 3 0 x 0 8 inches poly...

Страница 4: ...the backplate Swing the bottom edge of the module down and forward until you feel the unit snap shut Secure the module to the backplate using the M3x10mm screw supplied If required you may opt to use...

Страница 5: ...READ RX00 LED SITE CODE RX00 COLOUR 00 01 02 03 04 05 06 07 page KEYPAD SECTION TITLE DESCRIPTION set reader to read HID set reader to read EM set reader to read CASI set reader to read AWID set reade...

Страница 6: ...nd DATA Dorado 8 bit burst 8 digit CLOCK and DATA buffered 26 bit WIEGAND buffered 32 bit WIEGAND buffered 34 bit WIEGAND buffered To set the reader to buffer keystrokes and output them in the industr...

Страница 7: ...ode During the entry of a buffered PIN you have the option of making the reader issue a confirmation beep or an error triple beep on entering the PIN 6 8 0 9 4 7 5 1 2 3 During the entry of a buffered...

Страница 8: ...for accessing the many features supported by this reader 4 keypad programming guide RX standard LED configuration RX Demo RX buzzer RX AWE excluded from documentation RX MPS excluded from documentati...

Страница 9: ...ming guide To set WIEGAND Pass Through enter 101 once the reader has been placed into programming mode Configure reader to read HID proximity cards 6 8 0 9 4 7 5 1 2 3 DISABLE function WIEGAND Pass Th...

Страница 10: ...he many features supported by this reader 4 keypad programming guide To set ENABLE AWID function enter 131 once the reader has been placed into programming mode Configure reader to read AWID proximity...

Страница 11: ...e many features supported by this reader 4 keypad programming guide To set 26 bit Wiegand enter 201 once the reader has been placed into programming mode Configure reader to read MIFARE proximity card...

Страница 12: ...ntering programming mode the reader will time out after approximately 30 seconds if no keys are pressed for that duration Any changes you may have made to values or settings will be lost Remember to k...

Отзывы: