3MillID S-Gang Keypad Reader Скачать руководство пользователя страница 4

3millID   9249 S. Broadway   Building #200   Suite 826   Highlands Ranch   CO 80129

+1 303 475 4972

[email protected]

© 3millID

100-02640-A

www.3millid.com

Remove module securement screw. Lever bottom edge of reader module away 
from the backplate, and lift up.

Fix reader BACKPLATE to a plain surface finish, using suitable screw fixings 
having a diameter no greater than 4mm (0.15 inch).

If printed full scale, you may use the drawing below as a fixing template.

MEASURE and CHECK DIMENSIONS before use.

NOTE:
Mounting this reader on (or near) metal may impair the read range of the unit.

3.

installation guide

Fasten the reader module, ensuring the top-edge fixings engage correctly with the
recesses at the top of the backplate. Swing the bottom edge of the module down
and forward until you feel the unit ‘snap’ shut.
Secure the module to the backplate using the M3x10mm screw supplied.

If required, you may opt to use a security screw to the sizes shown here.

Following installation, it is recommended the access control system and control
units are subjected to a maintenance and operational test procedure.

TEST COMPLETE SYSTEM AT LEAST ONCE A YEAR

i

1

2

i

3

1

Once  the  backplate  is 
secured, 

make 

wire 

connections to the reader, in 
accordance  with  the  screw 
terminal  connections  shown 
on  Page  3  of  this  document 
and  your  control  panel 
requirements.  Ensure  the 
cable  does  not  impair  or 
prevent  the  reader  module 
being secured.

i

2

3

83.3mm (US)

3.3 inches

60.3mm (UK/EU)

2.4 inches

53.0mm

2.1 inches

53.0mm

2.1 inches

15mm

0.6 inch

centreline

BACKPLATE

Fixing holes - 4mm 
maximum diameter.

MANUAL

3M

S-Gang

Keypad

4

Содержание S-Gang Keypad Reader

Страница 1: ...the reader may be fixed directly onto a US electrical backbox This powerfully secure and innovative reader has a beautifully clean aesthetic and a bright RGB LED that can be applied to many applicatio...

Страница 2: ...5 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference...

Страница 3: ...tage Rest 4Vdc Active 1Vdc Data Output Wiegand Clock Data Custom Outputs Indication 1 RGB LED RGB illuminated keypad Sounder Integral speaker dimensions 120mm x 76mm x 21mm 4 7 x 3 0 x 0 8 inches poly...

Страница 4: ...the backplate Swing the bottom edge of the module down and forward until you feel the unit snap shut Secure the module to the backplate using the M3x10mm screw supplied If required you may opt to use...

Страница 5: ...READ RX00 LED SITE CODE RX00 COLOUR 00 01 02 03 04 05 06 07 page KEYPAD SECTION TITLE DESCRIPTION set reader to read HID set reader to read EM set reader to read CASI set reader to read AWID set reade...

Страница 6: ...nd DATA Dorado 8 bit burst 8 digit CLOCK and DATA buffered 26 bit WIEGAND buffered 32 bit WIEGAND buffered 34 bit WIEGAND buffered To set the reader to buffer keystrokes and output them in the industr...

Страница 7: ...ode During the entry of a buffered PIN you have the option of making the reader issue a confirmation beep or an error triple beep on entering the PIN 6 8 0 9 4 7 5 1 2 3 During the entry of a buffered...

Страница 8: ...for accessing the many features supported by this reader 4 keypad programming guide RX standard LED configuration RX Demo RX buzzer RX AWE excluded from documentation RX MPS excluded from documentati...

Страница 9: ...ming guide To set WIEGAND Pass Through enter 101 once the reader has been placed into programming mode Configure reader to read HID proximity cards 6 8 0 9 4 7 5 1 2 3 DISABLE function WIEGAND Pass Th...

Страница 10: ...he many features supported by this reader 4 keypad programming guide To set ENABLE AWID function enter 131 once the reader has been placed into programming mode Configure reader to read AWID proximity...

Страница 11: ...e many features supported by this reader 4 keypad programming guide To set 26 bit Wiegand enter 201 once the reader has been placed into programming mode Configure reader to read MIFARE proximity card...

Страница 12: ...ntering programming mode the reader will time out after approximately 30 seconds if no keys are pressed for that duration Any changes you may have made to values or settings will be lost Remember to k...

Отзывы: