19
Procedure
Work Surface
a) Access the dual inline package (DIP) switches SW1 and SW2 through a slot
located at the bottom of the chassis. Adjust SW1 to the LOUD position and
SW2 to the ON position with a small screwdriver (Figure 4).
b) Plug in the AC adapter. Note that the red high work surface lamp (M) is
illuminated with an audible alarm (slow chirping beep).
c) Adjust DIP switch SW1 to the SOFT position. Note that the loudness of the
alarm decreases.
d) Adjust DIP switch SW2 to the OFF position. Note that the audible alarm is
silenced.
e) Attach the 3M
™
Monitor/Table Mat Cord 2380D and the 3M
™
Workstation
Monitor 724 ground wire to the RSB using the two wires with alligator
clips. Set the resistance as follows and observe Workstation Monitor 724
output:
3.1 Megohms – Red work surface lamp (M) OFF.
4.3 Megohms – Red work surface lamp (M) ON.
f) Disconnect the cords from the RSB.
g) Connect the ring terminal end of the Workstation Monitor 724 ground wire to
the metal snap of the Monitor/Table Mat Cord 2380D. The red work surface
lamp (M) should now be OFF.
Attach 3M
™
Workstation
Monitor 724 Ground
Cord or AC Adapter
Ground Wire
Workstation Monitor
724 Ground Cord
3M
™
Monitor Table Mat Cord
3M
™
Monitor Table Mat Cord
Conductive/
Dissipative
Work Surface #1
Conductive/
Dissipative
Work Surface #2
3M
™
Workstation Monitor 724
Rear
AC Adapter
AC Adapter
Ground Wire
3M
™
Dual
Remote Splitter
3M
™
Remote
Input Jack
Work Surface
Ground Cord
Ground
Ground
Figure 15 – 3M
™
Workstation Monitor 724 wire connection diagram for two work stations.
Содержание Workstation Monitor 724
Страница 1: ...1 User s Guide 3M Workstation Monitor 724 ...