3M W-3060 Скачать руководство пользователя страница 4

Important 

Before use, the wearer must read and understand these 

User Instructions

.  Keep these 

User Instructions

 for 

reference.  

General Description 

These 3M

TM

 Airline Adapter and Regulating Kits, when used in conjunction with a 3M™ 6000DIN or 7000 

Series Full Facepiece, create a slight positive pressure atmosphere.  The slight positive pressure helps to 
prevent airborne contaminants from entering the headpiece.  These kits when used in a complete system 
(supplied air hose, valve, breathing tube and headpiece) are classified as a Type C or CE supplied air 
respirator by NIOSH. 

W-3061 Air Regulating Kit 

This air regulating kit is designed to provide those 3M full facepiece respirators which are approved for use 
with it, a continuous airflow of 4 to 15 cfm (115 to 425 lpm).  The control knob is set manually between 
upper and lower airflow limits to suit the comfort requirements of the user. 

 

W-3060-25, W-3060-50, W-3060-100 Airline Adapter Kits

 

These adapter kits are designed to provide those 3M full facepiece respirators which are approved for use 
with it, a continuous airflow of 4 to 15 cfm (115 to 425 lpm).  The control knob is set manually between 
upper and lower airflow limits to suit the comfort requirements of the user.  The user may choose the kit that 
includes the hose length to best fit their application, either 25, 50 or 100ft. 
   

W-3197 Air Regulating Kit-low pressure (7-12 psig)

 

The 3M™ Low Pressure Air Regulating Kit is designed to provide those 3M full facepiece respirators which 
are approved for use with it, a continuous airflow of 4 to 15 cfm (115 to 425 lpm).  When used as part of an 
approved system with the 3M™ Supplied Air Hose W-3020, the W-3197 will provide airflow within the 
specified range when the air pressure at the point of connection for the hose is between 7 and 12 psig (0.5 to 
0.8 kg/cm

2

), dependent on the hose length. 

 

NIOSH Approval 

Any NIOSH approval appearing on these air control devices is strictly limited to its use in an approved 
system only in full accordance with the specifications and limitations under said approval. 

These 3M™ Airline Adapter and Regulating Kits are to be used with 3M™ 6000DIN or 7000 Series Full 
Facepieces as specified in the NIOSH approval.  When used as directed by the NIOSH approval, and in 
accordance with the use and maintenance instructions, these systems can provide positive pressure supplied 
air respiratory protection. 

 

NIOSH Cautions and Limitations 

A–  Not for use in atmospheres containing less than 19.5 percent oxygen. 
B–  Not for use in atmospheres immediately dangerous to life or health. 
C–  Do not exceed maximum use concentrations established by regulatory standards. 
D–  Air-line respirators can only be used when the respirators are supplied with respirable air meeting the 

requirements of CGA G-7.1 Grade D or higher quality. 

E–  Use only the pressure ranges and hose lengths specified in the User’s Instructions. 
J–  Failure to properly use and maintain this product could result in injury or death. 
M– All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, 

OSHA, and other applicable regulations. 

 

4

Содержание W-3060

Страница 1: ...Air Regulating Kit W 3197 with W 3195 Low Pressure Connector Important Keep these User Instructions for reference This product helps protect against certain airborne contaminants Misuse may result in sickness or death For proper use see supervisor User Instructions or call 3M in U S A 1 800 243 4630 In Canada call Technical Service at 1 800 267 4414 ...

Страница 2: ...ntrol devices approved for use with the 3M 7000 or 6000DIN Series Full Facepieces must be operated within the supply pressure ranges and hose lengths stated in the Specifications section Failure to do so may affect respirator performance and result in sickness or death You must comply with OSHA standard 29 CFR 1910 134 which states that Airline couplings shall be incompatible with outlets for othe...

Страница 3: ...ar this respirator where Atmospheres are oxygen deficient Contaminant concentrations are unknown Contaminant concentrations are Immediately Dangerous to Life or Heath IDLH Contaminant concentrations exceed the assigned protection factor APF recommended for the applicable headpiece or the APF mandated by specific government standards whichever is lower Refer to the User instructions provided with t...

Страница 4: ...ose 3M full facepiece respirators which are approved for use with it a continuous airflow of 4 to 15 cfm 115 to 425 lpm When used as part of an approved system with the 3M Supplied Air Hose W 3020 the W 3197 will provide airflow within the specified range when the air pressure at the point of connection for the hose is between 7 and 12 psig 0 5 to 0 8 kg cm2 dependent on the hose length NIOSH Appr...

Страница 5: ...35 Hose Length Supply Pressure psig Supply Pressure kg cm2 25 ft 7 62 m 15 25 1 05 1 76 50 ft 15 24 m 18 25 1 27 1 76 100 ft 30 48 m 19 30 1 34 2 11 200 ft 60 96 m 25 40 1 76 2 81 300 ft 91 44 m 25 55 1 76 3 87 W 3197 Kit W 3195 Valve W 3255 Assembly 3M Compressed Air Hoses and Approved Lengths W 3020 Hose Length Supply Pressure psig Supply Pressure kg cm2 25 ft 7 62 m 7 11 0 5 0 77 50 ft 15 24 m ...

Страница 6: ... not be present when the air reaches the air control device Excessive amounts of water vapor and any particulate matter should also be removed as they may result in unpredictable behavior of the air control device The schematic diagram of the air purifier and pressure regulator equipment shows what should be installed in the main airline ahead of the connection for breathing air hoses Fig 1 Fig 1 ...

Страница 7: ...e D breathing air as described in the Compressed Gas Association Commodity Specification G 7 1 1997 in the United States In Canada refer to CSA standard Z180 1 table for the quality of compressed breathing air Failure to do so may result in sickness or death The line pressure must be kept within safe limits 125 psig 8 75 kg cm2 maximum Dirt oil and water unless trapped or filtered out may continue...

Страница 8: ...7000 Series User Instructions for installation of filter or cartridge adapters for use with filters and cartridges 3 Screw the W 3187 adapter into the center port Tighten securely so that the threaded fitting points to the right side of the facepiece as worn 4 Place the belt around the waist with the female end of the buckle on the right hand side and adjust for size and comfort Slide the plastic ...

Страница 9: ...Fig 4 9 Place the belt around your waist With the female part of the buckle on your right buckle it into place Slide the air regulating valve over to the right hip Fig 5 9 ...

Страница 10: ...that the breathing tube goes through should be positioned on your back approximately between the shoulder blades Note Positioning the breathing tube and shoulder strap over opposite shoulders will keep the breathing tube close to the body and helps to not restrict head movements It is also beneficial for the breathing tube to go over the right shoulder so any upward shoulder movements then tend to...

Страница 11: ...tire system must meet the requirements of the Fitting Instructions before entering any hazardous environment FITTING INSTRUCTIONS See the 3M Full Facepiece 6000DIN or 7000 Series User Instructions for details 11 ...

Страница 12: ...spirator performance and result in sickness or death Use of this respirator in atmospheres for which it was not NIOSH certified or designed may result in sickness or death Do not wear this respirator where Atmospheres are oxygen deficient Contaminant concentrations are unknown Contaminant concentrations are Immediately Dangerous to Life or Heath IDLH Contaminant concentrations exceed the assigned ...

Страница 13: ...g lanolin or other oils 3 Disinfect facepiece by soaking in a solution of quaternary ammonia disinfectant or sodium hypochloride 1 oz 30 ML household bleach in 2 gallons 7 5 L of water or other disinfectant 4 Rinse in fresh warm water and air dry in non contaminated atmosphere The cleaned respirator should be stored away from contaminated areas when not in use Clean the air control devices on thei...

Страница 14: ...RRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY EXCEPT OF TITLE AND AGAINST PATENT INFRINGEMENT LIMITATION OF LIABILITY Except as provided above 3M shall not be liable or responsible for any loss or damage whether direct indirect incidental special or consequential arising out of sale use or misuse of 3M OH ESD products or the user s inability to use such pr...

Отзывы: