3M W-3060 Скачать руководство пользователя страница 3

respirators, a written respiratory protection program must be implemented meeting all the requirements of 
OSHA 29 CFR 1910.134 such as training, fit testing, medical evaluation, and applicable OSHA substance 
specific standards.  In Canada, CSA standard Z94.4 requirements must be met and/or requirements of the 
applicable jurisdiction, as appropriate. 

 

Each person using this respirator must read and understand the information in these 

User Instructions 

before 

use.  Use of this respirator by untrained or unqualified persons, or use not in accordance with these 

User 

Instructions,

 

may adversely affect product performance and

 

result in sickness or death. 

 

Do not use if any parts are missing or damaged. 

 

Do not use with parts or accessories other than those manufactured by 3M as described in these 

User 

Instructions 

or on the NIOSH approval label for the respirator that you are using.  

Failure to do so may 

adversely affect respirator performance and result in sickness or death. 

 

Use of this respirator in atmospheres for which it was not NIOSH certified or designed 

may result in 

sickness or death.

  Do not wear this respirator where: 

–  Atmospheres are oxygen deficient 
–  Contaminant concentrations are unknown 
–  Contaminant concentrations are Immediately Dangerous to Life or Heath (IDLH) 
–  Contaminant concentrations exceed the assigned protection factor (APF) recommended for the applicable 

headpiece or the APF mandated by specific government standards, whichever is lower.  Refer to the 

User 

instructions

 provided with the applicable headpiece. 

 

Contaminants that are dangerous to your health include those that you may not be able to see or smell.  Leave 
the contaminated area immediately if any of the following conditions occur.  

Failure to do so may result in 

sickness or death. 

–  Any part of the system becomes damaged 
–  Airflow into the respirator decreases or stops 
–  Breathing becomes difficult 
–  You feel dizzy or your vision is impaired 
–  You taste or smell contaminants 
–  Your face, eyes, nose or mouth become(s) irritated 
–  You suspect that the concentration of contaminants may have reached levels at which this respirator may 

no longer provide adequate protection. 

 

Never alter or modify this assembly. 

 

Air supply piping, fittings, and compressors must have the capacity to deliver sufficient air volume (4 to 15 
cfm, 115 to 425 lpm) to operate the air regulating valve at the recommended pressure.  

 

 

USE INSTRUCTIONS AND LIMITATIONS  
 

 

3

Содержание W-3060

Страница 1: ...Air Regulating Kit W 3197 with W 3195 Low Pressure Connector Important Keep these User Instructions for reference This product helps protect against certain airborne contaminants Misuse may result in sickness or death For proper use see supervisor User Instructions or call 3M in U S A 1 800 243 4630 In Canada call Technical Service at 1 800 267 4414 ...

Страница 2: ...ntrol devices approved for use with the 3M 7000 or 6000DIN Series Full Facepieces must be operated within the supply pressure ranges and hose lengths stated in the Specifications section Failure to do so may affect respirator performance and result in sickness or death You must comply with OSHA standard 29 CFR 1910 134 which states that Airline couplings shall be incompatible with outlets for othe...

Страница 3: ...ar this respirator where Atmospheres are oxygen deficient Contaminant concentrations are unknown Contaminant concentrations are Immediately Dangerous to Life or Heath IDLH Contaminant concentrations exceed the assigned protection factor APF recommended for the applicable headpiece or the APF mandated by specific government standards whichever is lower Refer to the User instructions provided with t...

Страница 4: ...ose 3M full facepiece respirators which are approved for use with it a continuous airflow of 4 to 15 cfm 115 to 425 lpm When used as part of an approved system with the 3M Supplied Air Hose W 3020 the W 3197 will provide airflow within the specified range when the air pressure at the point of connection for the hose is between 7 and 12 psig 0 5 to 0 8 kg cm2 dependent on the hose length NIOSH Appr...

Страница 5: ...35 Hose Length Supply Pressure psig Supply Pressure kg cm2 25 ft 7 62 m 15 25 1 05 1 76 50 ft 15 24 m 18 25 1 27 1 76 100 ft 30 48 m 19 30 1 34 2 11 200 ft 60 96 m 25 40 1 76 2 81 300 ft 91 44 m 25 55 1 76 3 87 W 3197 Kit W 3195 Valve W 3255 Assembly 3M Compressed Air Hoses and Approved Lengths W 3020 Hose Length Supply Pressure psig Supply Pressure kg cm2 25 ft 7 62 m 7 11 0 5 0 77 50 ft 15 24 m ...

Страница 6: ... not be present when the air reaches the air control device Excessive amounts of water vapor and any particulate matter should also be removed as they may result in unpredictable behavior of the air control device The schematic diagram of the air purifier and pressure regulator equipment shows what should be installed in the main airline ahead of the connection for breathing air hoses Fig 1 Fig 1 ...

Страница 7: ...e D breathing air as described in the Compressed Gas Association Commodity Specification G 7 1 1997 in the United States In Canada refer to CSA standard Z180 1 table for the quality of compressed breathing air Failure to do so may result in sickness or death The line pressure must be kept within safe limits 125 psig 8 75 kg cm2 maximum Dirt oil and water unless trapped or filtered out may continue...

Страница 8: ...7000 Series User Instructions for installation of filter or cartridge adapters for use with filters and cartridges 3 Screw the W 3187 adapter into the center port Tighten securely so that the threaded fitting points to the right side of the facepiece as worn 4 Place the belt around the waist with the female end of the buckle on the right hand side and adjust for size and comfort Slide the plastic ...

Страница 9: ...Fig 4 9 Place the belt around your waist With the female part of the buckle on your right buckle it into place Slide the air regulating valve over to the right hip Fig 5 9 ...

Страница 10: ...that the breathing tube goes through should be positioned on your back approximately between the shoulder blades Note Positioning the breathing tube and shoulder strap over opposite shoulders will keep the breathing tube close to the body and helps to not restrict head movements It is also beneficial for the breathing tube to go over the right shoulder so any upward shoulder movements then tend to...

Страница 11: ...tire system must meet the requirements of the Fitting Instructions before entering any hazardous environment FITTING INSTRUCTIONS See the 3M Full Facepiece 6000DIN or 7000 Series User Instructions for details 11 ...

Страница 12: ...spirator performance and result in sickness or death Use of this respirator in atmospheres for which it was not NIOSH certified or designed may result in sickness or death Do not wear this respirator where Atmospheres are oxygen deficient Contaminant concentrations are unknown Contaminant concentrations are Immediately Dangerous to Life or Heath IDLH Contaminant concentrations exceed the assigned ...

Страница 13: ...g lanolin or other oils 3 Disinfect facepiece by soaking in a solution of quaternary ammonia disinfectant or sodium hypochloride 1 oz 30 ML household bleach in 2 gallons 7 5 L of water or other disinfectant 4 Rinse in fresh warm water and air dry in non contaminated atmosphere The cleaned respirator should be stored away from contaminated areas when not in use Clean the air control devices on thei...

Страница 14: ...RRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY EXCEPT OF TITLE AND AGAINST PATENT INFRINGEMENT LIMITATION OF LIABILITY Except as provided above 3M shall not be liable or responsible for any loss or damage whether direct indirect incidental special or consequential arising out of sale use or misuse of 3M OH ESD products or the user s inability to use such pr...