background image

3M™ MicroTouch™ Controller RX182 Reference Guide 

 

3M Touch Systems, Inc. Proprietary Information 

The information in this document is subject to change without notice. No part of this document may be reproduced or transmitted 
in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of 3M Touch 
Systems, Inc. 3M may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights 
covering subject matter in this document. The furnishing of this document does not give you license to these patents, trademarks, 
copyrights, or other intellectual property except as expressly provided in any written license agreement from 3M Touch Systems, 
Inc. 

The information provided in this document is intended as a guide only. For the latest detailed engineering specifications, please 
contact your 3M Touch Systems, Inc. Application Engineer. 3M Touch Systems, Inc. is committed to continually improving 
product designs. As a result, product specifications may be subject to change without notification. 

"RoHS compliant 2005/95/EC" means that the product or part does not contain any of the following substances in excess of the 
following maximum concentration values in any homogeneous material, unless the substance is in an application that is exempt 
under RoHS: (a) 0.1% (by weight) for lead, mercury, hexavalent chromium, polybrominated biphenyls or polybrominated 
diphenyl ethers; or (b) 0.01% (by weight) for cadmium. This information represents 3M’s knowledge and belief, which may be 
based in whole or in part on information provided by third party suppliers to 3M. 

NOTICE: 

Given the variety of factors that can affect the use and performance of a 3M Touch Systems, Inc. product (the 

“Product”), including that solid state equipment has operation characteristics different from electromechanical equipment, some 
of which factors are uniquely within User’s knowledge and control, it is essential that User evaluate the 3M Touch Systems, Inc. 
Product and software to determine whether it is suitable for User’s particular purpose and suitable for User’s method of 
application. 3M Touch Systems, Inc. statements, engineering/technical information, and recommendations are provided for 
User’s convenience, but their accuracy or completeness is not warranted. 3M Touch Systems, Inc. products and software are not 
specifically designed for use in medical devices as defined by United States federal law. 3M Touch Systems, Inc. products and 
software should not be used in such applications without 3M Touch Systems, Inc. express written consent. User should contact 
its sales representative if User’s opportunity involves a medical device application. 

IMPORTANT NOTICE TO PURCHASER: 

Specifications are subject to change without notice. These 3M Touch Systems, 

Inc. Products and software are warranted to meet their published specifications from the date of shipment and for the period 
stated in the specification

. 3M Touch Systems, Inc. makes no additional warranties, express or implied, including but not 

limited to any implied warranties of merchantability or fitness for a particular purpose. 

User is responsible for determining 

whether the 3M Touch Systems, Inc. Products and software are fit for User’s particular purpose and suitable for its method of 
production, including intellectual property liability for User's application. If the Product, software or software media is proven 
not to have met 3M Touch Systems, Inc. warranty, then 3M Touch Systems, Inc. sole obligation and User’s and Purchaser’s 

exclusive remedy

, will be, at 3M Touch Systems, Inc. option, to repair or replace that Product quantity or software media or to 

refund its purchase price. 3M Touch Systems, Inc. has no obligation under 3M Touch Systems, Inc. warranty for any Product, 
software or software media that has been modified or damaged through misuse, accident, neglect, or subsequent manufacturing 
operations or assemblies by anyone other than 3M Touch Systems, Inc.

 3M Touch Systems, Inc. shall not be liable in any 

action against it in any way related to the Products or software for any loss or damages, whether non-specified direct, 
indirect, special, incidental or consequential (including downtime, loss of profits or goodwill) regardless of the legal 
theory asserted.

 

© 3M  2004-2009  All rights reserved. 

Document Title

: 3M

TM

 MicroTouch

TM

 Controller RX182 Reference Guide

 

Document Number:  19-272, Version 22 

3M, the 3M logo, MicroTouch, and the MicroTouch logo are either registered trademarks or trademarks of 3M in the United 
States and/or other countries. 

Windows and/or other Microsoft products referenced herein are either registered trademarks or trademarks of Microsoft 
Corporation in the U.S. and/or other countries.  

All other trademarks are the property of their respective owners. 
 

Содержание Touch Screen Controller RX182

Страница 1: ...stems Inc Proprietary Information 3M MicroTouch Controller RX182 Reference Guide Formerly SC800 Serial Resistive Read and understand all safety information contained in this document before using this...

Страница 2: ...ot warranted 3M Touch Systems Inc products and software are not specifically designed for use in medical devices as defined by United States federal law 3M Touch Systems Inc products and software shou...

Страница 3: ...stablishing the Data Connection 10 Mounting the Controller 11 Supplying Power to the Controller 11 Mounting the Sensor 12 Sensor Cable Connector 12 Status Light LED Diagnostics 13 Turning On Your Syst...

Страница 4: ...uch Systems Inc Proprietary Information Restore Defaults 24 Set Controller Number Error Bookmark not defined Unit Type 24 Appendix A RX182 Controller Specifications Technical Specifications 28 Storage...

Страница 5: ...ted to being a premier supplier in touch systems throughout the world As a 3M Touch Systems customer you are aware that we have strong internal programs that meet or exceed environmental regulations o...

Страница 6: ...ury or death Do not use a damaged power supply Do not use a power cord that is frayed or otherwise damaged CAUTION To reduce the risks associated with improper disposal which if not avoided may result...

Страница 7: ...through Friday 8 30 a m to 5 30 p m with limited call back service after 5 30 p m until 8 00 p m US Eastern Standard Time 9 a m to 5 p m throughout Europe You can contact 3M Touch Systems Technical Su...

Страница 8: ......

Страница 9: ...nd 1 stop bit To integrate and test the RX182 controller you need the following items A 8 wire resistive sensor A method of establishing the serial data communication between the controller and your s...

Страница 10: ...or JP2 You can use a standard 3M MicroTouch RS 232 plug and play cable P N 7319630 or an equivalent interconnect One end of this cable plugs into the RS 232 connector JP2 on the RX182 controller The o...

Страница 11: ...should be mounted in line with the sensor cable exit point to minimize cable flexing The controller should be mounted internally behind or on the side of the display on stand offs to allow room for th...

Страница 12: ...lex connector Refer to Table 1 for more information on actual cable connections Unlike using JP4 to supply power you can only use 5VDC at the serial interface 1 Obtain an 8 pin Molex connector 51004 0...

Страница 13: ...sensor the LED becomes bright as long as the controller detects a touch A flashing or blinking LED during power up indicates the controller s power on self test failed Refer to the following table fo...

Страница 14: ...or many operating systems including Windows Vista XP XP embedded 2000 9X Windows Me Windows CE and Windows NT 4 0 refer to the website for a complete listing You must be sure to install the correct so...

Страница 15: ...d includes the command syntax the default value how the command works and the expected response from the controller Controller Default Settings Communication Parameters The RX182 controller communicat...

Страница 16: ...ed in the following table are those that 3M Touch Systems currently uses for development and recommends that you use only these commands Commands to the controller are sent on the signal Receive Data...

Страница 17: ...ontrol character is 01 If you are working with an IBM PC compatible system in terminal mode the SOH control character returns a character to the sensor The response which always follows the header is...

Страница 18: ...tialize the controller select operating modes specify data formats and execute diagnostic functions Most touch system users do not have to use firmware commands to use their touch systems For example...

Страница 19: ...Number W002 Used to determine a controller ID number for multiple monitor applications Unit Type UT Returns controller unit type string and status Calibrate 3 Point Syntax SOH C3 CR Response SOH 0 CR...

Страница 20: ...o register a calibration touch Therefore you can touch the coordinate target hold for a few seconds and then lift off Instructing users to touch this way results in a more accurate calibration The con...

Страница 21: ...n the following format SXxYy S Status byte first byte of data Refer to Table 4 Xx X horizontal coordinate data second and third bytes of data Yy Y vertical coordinate data fourth and fifth bytes of da...

Страница 22: ...ty bit changes from 1 to 0 touch liftoff the controller outputs one final set of X Y coordinate data with the bit equal to 0 and the X Y coordinate data equal to the last touch point S7 Packet synchro...

Страница 23: ...Returns a 6 character identifier which describes the controller type and the firmware version number The output identity for the RX182 controller is SCXxxx Reset Syntax SOH R CR Response SOH 0 CR Posi...

Страница 24: ...Tablet Operating Mode Mode Stream Return to Factory Calibration Yes Note After you issue a Restore Defaults command you must recalibrate your sensor Set Controller Number a multi step command Syntax...

Страница 25: ...her 4 wire controller RX142 or an 8 wire controller RX182 Indicates no additional features configured Ss Two ASCII characters that provide status information about the controller hardware The two char...

Страница 26: ......

Страница 27: ...pecifications such as power requirements environmental requirements and cable connectors The RX182 controller is a compact RS 232 serial controller This controller was designed to be mounted inside yo...

Страница 28: ...ZS 3548 1995 CISPR 22 Class B ITE Emissions Aus Class B Compliant RFI EN 61000 4 3 ENV 50140 Class A Compliant CRFI EN 61000 4 6 N A Cable 3 meters long N A EFT Burst Immunity EN 61000 4 4 Class B Com...

Страница 29: ...on 9 of IEC 61000 4 2 Compliant 1 false touch allowed 20 kV Air Discharge Class 1 per section 9 of IEC 61000 4 2 Compliant Normal Operation No false touches ESD discharges to a sensor connected to the...